-14-
■
Adjustment
5. Gain (Signal Amplitude) adjustments
Equipment
Oscilloscope
Input Signal
16 step gray scale signal
Enter the Service mode.
Adjust the amplitude of part A to be below value for each
test point by the or - button.
5-1
Input mode
Computer
Item no.
Test Point
Adjustment value
13
TP-R1
4.1 ± 0.1 Vp-p
14
TP-G1
4.1 ± 0.1 Vp-p
15
TP-B1
4.1 ± 0.1 Vp-p
5-2
Input mode
AV (NTSC)
13
TP-R1
4.1 ± 0.1 Vp-p
14
TP-G1
4.1 ± 0.1 Vp-p
15
TP-B1
4.1 ± 0.1 Vp-p
A
7. Flicker Reduction
Input mode
Computer
Input Signal
1dot computer signal
Enter the Service mode.
Adjust to be minimum flicker for each color by the Volume
+ or - button.
Item no.
Screen
19
Only red color picture
20
Only green color picture
21
Only blue color picture
8. White Balance Adjustments
Input Signal
16 step gray scale signal
Enter the Service mode.
Adjust each value of below item to be good white balance
by the or - button.
Item no. Imput Mode
17 and 18
Computer
17 and 18
AV (NTSC)
(17:Red, 18:Blue)
Note:
The white balance of Computer and AV pictures must be
same.
6. 50% Luminance (Contrast Linearity)
Adjustments
Input Signal
16 step gray scale signal
Enter the Service mode.
If the black or white saturated picture can be seen, adjust
the value of below item to be reduced it by the or
- button.
Item no. Imput Mode
11
Computer
11
AV (NTSC)
(9. Color Shading Correction)
For the color shading correction, the proper computer and
“ Color Shading Correction” software are needed.
The software can be ordered as follows.
Note:
The software for the previous model “PLC-XW20” or “PLC-
SW20” can not be used.
COLOR SHADING CORRECTION
Service Parts No. 645 056 6288
Содержание PLC-SW20A
Страница 35: ... 35 Electrical Parts List Key No Part No Description Key No Part No Description ...
Страница 39: ...Memo ...
Страница 40: ...AUG 2002 Printed in Japan SANYO Electric Co Ltd ...