-29-
Group 100 H8 Option
0
Lamp Time Monitor
0~8738
Read Only
1
RS232C Baudrate
0 ~ 1
0: 19200bps1: 9600bps
2
3
Cooling Time
3
1 ~ 15
Cooling time1:30 sec.3:90 sec.15:450 sec.
4
Hi-Land SW
0
0 ~ 3
0: Normal Mode1~3: High-Land Mode 1-3
5
6
Lamp Total Time
0~65535
Read only
7
Net Board RESET
0 ~ 1
Not used
8
9
Reset SW
0 ~ 10
Resets User Setting data when this value is set to 10
10
Color Shading SW
0 ~ 1
0:Color Compensation Off, 1:Color Compensation On
11
RC Enable/Disable
0
0 ~ 3
0:Enable 1:Disable
12
Lamp Dim Level
10
0 ~ 15
13
Lamp Warning Time
0~65535
14
15
Video Mute Forced Off
0 ~ 1
0:VideoMuteOn(Normal) 1:Video Mute Forced Off
16
Safety FAN Control Fix SW
0 ~ 5
0:Normal 1:Normal Min2:Normal Max3:Eco Min4:Eco Max
17
HDCP Option
0
0 ~ 3
0: XGA 1; other than XGA
18
HDCP Reset
0
0 ~ 10
19
Group: 101PW Option
0
Shootout Mode
0
0 ~ 1
1: Shoot Out Mode Enable0: Disable
1
2
NOBRAND
0
0 ~ 1
0:Normal1:NOBRAND
3
4
HDCP OverScan Rate
0
0 ~ 5
Group: 110 Dimmer Processing
0
DIMMER_CTRL_LEVEL1
7
0~255
Dimmer Brightness Level1 Data: Dimmer Level1 when less than this value.
1
DIMMER_CTRL_LEVEL2
14
0~255
Dimmer Brightness Level2 Data: Dimmer Level2 when less than this value.
2
DIMMER_CTRL_LEVEL3
21
0~255
Dimmer Brightness Level3 Data: Dimmer Level3 when less than this value.
3
DIMMER_CTRL_LEVEL4
28
0~255
Dimmer Brightness Level4 Data: Dimmer Level4 when less than this value.
4
DIMMER_CTRL_LEVEL5
35
0~255
Dimmer Brightness Level5 Data: Dimmer Level5 when less than this value.
5
DIMMER_CTRL_LEVEL6
42
0~255
Dimmer Brightness Level6 Data: Dimmer Level6 when less than this value.
6
DIMMER_CTRL_LEVEL7
49
0~255
Dimmer Brightness Level7 Data: Dimmer Level7 when less than this value.
7
DIMMER_CTRL_LEVEL8
56
0~255
Dimmer Brightness Level8 Data: Dimmer Level8 when less than this value.
8
DIMMER_CTRL_LEVEL9
63
0~255
Dimmer Brightness Level9 Data: Dimmer Level9 when less than this value.
9
DIMMER_CTRL_LEVEL10
70
0~255
Dimmer Brightness Level10 Data: Dimmer Level10 when less than this value.
10
DIMMER_CTRL_LEVEL11
77
0~255
Dimmer Brightness Level11 Data: Dimmer Level11 when less than this value.
11
DIMMER_CTRL_LEVEL12
84
0~255
Dimmer Brightness Level12 Data: Dimmer Level12 when less than this value.
12
DIMMER_CTRL_LEVEL13
91
0~255
Dimmer Brightness Level13 Data: Dimmer Level13 when less than this value.
13
DIMMER_CTRL_LEVEL14
98
0~255
Dimmer Brightness Level14 Data: Dimmer Level14 when less than this value.
14
DIMMER_CTRL_LEVEL15
105
0~255
Dimmer Brightness Level15 Data: Dimmer Level15 when less than this value.
15
DIMMER_AVERAGE_POINT
4
1 ~ 16
Average count for Dimmer Brightness Data
16
DIMMER_AVERAGE_DATA
-
0 ~ 255
Average Value for Dimmer Brightness Data * Read Only(8 bit)
17
DIMMER_LEVEL_AUTO
-
0 ~ 15
Dimmer Level effective in auto-dimmer mode. 0 fixed other than auto mode (Read Only)
18
DIMMER_LEVEL_NONAUTO
-
0 ~ 15
Dimmer Level effective other than auto-dimmer mode
Group: 111 Fan Control
0
FAN_TEMP_A_WARNING
55/59
30 ~ 100
Temperature A to judge the abnormal temperature, for surrounding temperature
SVGA/XGA
1
FAN_TEMP_B_WARNING
58/60
30 ~ 100
Temperature B to judge the abnormal temperature, for Panels
SVGA/XGA
2
FAN_TEMP_C_WARNING
71/73
30 ~ 100
Temperature C to judge the abnormal temperature, for Lamp
SVGA/XGA
3
FAN_TEMP_B-A_WARNING
100
0 ~ 100
Temperature B-A to judge the abnormal temperature, for detecting clogged filter
4
FAN_TEMP_C-A_WARNING
100
0 ~ 100
Temperature C-A to judge the abnormal temperature, for detecting clogged filter
5
FAN_CONTROL_SW
1
0 or 1
0: Auto Fan Control 1:Manual Control
6
FAN_1_SPEED_CTRL
135
0 ~ 255
Manual Adjustment Mode when FAN_CONTROL_SW=1
7
FAN_2_SPEED_CTRL
135
0 ~ 255
8
9
FAN_1_SPEED_MONI
-
0 ~ 255
Fan Speed Monitor when FAN_CONTROL_SW=0, Read Only
10
FAN_2_SPEED_MONI
-
0 ~ 255
11
12
FAN_TEMP_A_MONI
-
-
Read Only
13
FAN_TEMP_B_MONI
-
-
14
FAN_TEMP_C_MONI
-
-
15
16
TEMP_UPWARNING_TIME
0
0 ~ 5
+15 degrees is added to Abnormal Temperature Value during x min after power on.
17
NOR_TEMP_FAN1_MIN
42/48
Control Start Temperature for FAN1 at Normal Mode
SVGA/XGA
18
NOR_TEMP_FAN1_MAX
48/54
Control End Temperature for FAN1 at Normal Mode
SVGA/XGA
19
NOR_TEMP_FAN2_MIN
42/48
0~255
Control Start Temperature for FAN2 at Normal Mode
SVGA/XGA
20
NOR_TEMP_FAN2_MAX
48/54
Control End Temperature for FAN2 at Normal Mode
SVGA/XGA
21
22
23
NOR_VALU_FAN1_MIN
75
Minimum Control Value for FAN1 at Normal Mode (0: Fan Voltage 0V, 255: Fan Voltage 25.5V)
24
NOR_VALU_FAN1_MAX
135
Maximum Control Value for FAN1 at Normal Mode
25
NOR_VALU_FAN2_MIN
90
0~255
Minimum Control Value for FAN2 at Normal Mode
26
NOR_VALU_FAN2_MAX
135
Maximum Control Value for FAN2 at Normal Mode
27
28
29
ECO_TEMP_FAN1_MIN
41/47
Control Start Temperature for FAN1 at Eco Mode
SVGA/XGA
30
ECO_TEMP_FAN1_MAX
47/54
Control End Temperature for for FAN1 at Eco Mode
SVGA/XGA
31
ECOTEMP_FAN2_MIN
41/47
0~255
Control Start Temperature for FAN2 at Eco Mode
SVGA/XGA
32
ECO_TEMP_FAN2_MAX
47/54
Control End Temperature for for FAN2 at Eco Mode
SVGA/XGA
No.
Adjustment Item
Initial Value
Range
Input source / Description
Electrical Adjustments