-26-
[Adjustment Condition]
●
Input signal
Video signal .......................... 1.0Vp-p/75
Ω
terminated, 16 steps gray
scale (Composite video signal)
Computer signal .................... 0.7Vp-p/75
Ω
terminated, 16 steps gray
scale pattern (SVGA)
Component Video signal ...... 0.7Vp-p/75
Ω
terminated, 16 steps gray
scale (Component video signal with
480p or 1080i format)
●
Picture control mode .............. “STANDARD” mode unless otherwise
noted.
Note:
* Please refer to “Service Adjustment Menu Operation” for entering the service mode and adjusting the service
data.
White 100%
Black 100%
●
Circuit Adjustments
CAUTION: The each circuit has been made by the fine adjustment at factory. Do not attempt to adjust the follow-
ing adjustments except requiring the readjustments in servicing otherwise it may cause loss of per-
formance and product safety.
Electrical Adjustments
16 steps gray scale pattern
After replacing the Power Board, PF.C. Board, readjust
the Output voltage adjustment as follows.
1. Connect a digital voltmeter to pins 1 (+) and 3 (-) of
K6D
.
2. Adjust the voltage by using
VR611
as following.
AC Input
Reading
230V 370V
±2V
Caution:
Be sure to connect the lamp when taking this adjust-
ment.
Output Voltage adjustment
1. Set the lamp mode to “ECO” with the menu function.
2. Enter the service mode and select item no. “
74
”. Set
data value to “
1
”.
3. Connect a digital voltmeter to test point “
TP12V1
”
(+) and chassis ground (-). Select item no. “
75
” and
adjust the voltage to be
8.0
±0.1Vdc by changing
the Data value.
4. Connect a digital voltmeter to test point “
TP12V2
”
(+) and chassis ground (-). Select item no. “
76
” and
adjust the voltage to be
9.0
±0.1Vdc by changing
the Data value.
5. Select item no. “
74
” and set data value to “
3
”.
6. Connect a digital voltmeter to test point “
TP12V1
”
(+) and chassis ground (-). Select item no. “
77
” and
adjust the voltage to be
13.5
±0.1Vdc by changing
the Data value.
7. Connect a digital voltmeter to test point “
TP12V2
”
(+) and chassis ground (-). Select item no. “
78
” and
adjust the voltage to be
13.5
±0.1Vdc by changing
the Data value.
8. Select item no. “
74
” and set Data value to “
0
”, and
set the lamp mode to “Normal” with the menu func-
tion.
z
Fan Voltage adjustment
* This adjustment is not required even if the power
board is replaced because this adjustment is carried
out before parts shipment.
Содержание PLC-SU25
Страница 50: ... 50 IC Block Diagrams AD8075 Selector IC201 AD8183ARU Selector IC1201 AN7513 Audio Amp IC5001 ...
Страница 51: ... 51 AN5870SB RGB SW IC5201 IC Block Diagrams AD9884AKS A D IC8201 ...
Страница 54: ... 54 IC Block Diagrams CXD3526GG LCD Driver Timing Generator IC401 FA5502 P F Control IC611 ...
Страница 55: ... 55 LA7217 Sync Separator IC5361 M62392 D A IC3561 IC Block Diagrams ...
Страница 56: ... 56 NJM2284M Switch IC2101 IC Block Diagrams M62393 D A IC281 IC7801 ...
Страница 57: ... 57 PW164B 10 System Control Scan Converter IC301 IC Block Diagrams STR Z2156 Power Switching Control IC631 ...
Страница 82: ...MB3 SU4000 MB3 SU2500 82 46 44 44 46 44 44 Mechanical Parts List 46 57 56 46 46 Optical PARTS ...
Страница 83: ...MB3 SU4000 MB3 SU2500 83 44 44 54 67 Red 68 Green 69 Blue 44 44 44 Mechanical Parts List ...
Страница 85: ...MB3 SU4000 MB3 SU2500 85 52 a 52 45 45 45 45 52 Mechanical Parts List ...
Страница 86: ...MB3 SU4000 MB3 SU2500 86 Mechanical Parts List 58 70 63 71 57 60 65 59 64 66 51 55 62 ...
Страница 88: ... MB3A Jan 2003 BB 400 Printed in Japan SANYO Electric Co Ltd ...
Страница 92: ...Diagrams Drawings MB3A ...
Страница 100: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 A B C D E F G H I J K A B C D E F G H I J K L A10 SCH_MB3A ...