PLC-HF15000L Expand Serial Command Functional Specifications
39/105
8.7.13 CF_VPOS Command
Command
“CF_VPOS_%1” [CR]
%1
“015” --------------------- +15
“014” --------------------- +14
:
“001” --------------------- +1
“000” --------------------- ±0
“
‐
01” ---------------------
‐
1
:
“
‐
14” ---------------------
‐
14
“
‐
15” ---------------------
‐
15
“UP” --------------------- Increment setting value of Vposition by 1
“DN” --------------------- Decrement setting value of Vposition by 1
Details
Set V Position (Available only in the normal Power ON status)
*When selected screen mode is a setting except Custom, return “101” [CR] and
the command is not executed.
* When input is no signal, return “101” [CR] and the command is not executed.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.7.14 CF_HSCALE Command
Command
“CF_HSCALE_%1” [CR]
%1
“035” ---------------------- +35
“031” ---------------------- +31
:
“002” ---------------------- +2
“001” ---------------------- +1
“000” ---------------------- ±0
“
‐
01” ---------------------
‐
1
“
‐
02” ---------------------
‐
2
:
“
‐
31” ---------------------
‐
31
“
‐
32” ---------------------
‐
32
“UP” --------------------- Increment setting value of Hscale by 1
“DN” --------------------- Decrement setting value of Hscale by 1
Details
Set Hscale (Available only in the normal Power ON status)
*When selected screen mode is a setting except Custom, return “101” [CR] and
the command is not executed.
* When input is no signal, return “101” [CR] and the command is not executed.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]