8.4.5 CF_COLMNSAV Command
Command
“CF_COLMNSAV_%1” [CR]
%1
“000 – 009” ---------------- Specify the area to store
Details
Store current setting status of Color Management to the area specified in %1.
(Available only in the normal Power ON status)
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]
8.4.6 CF_COLMNLD Command
Command
“CF_COLMNLD_%1” [CR]
%1
“000 – 009” ---------------- Specify the area to store
Details
Retrieve Color Management setting status from the area specified in %1.
(Available only in the normal Power ON status)
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]
8.4.7 CF_APCTRL Command
Command
“CF_APCTRL_%1” [CR]
%1
“L1” ------------------- Set Auto Picture Control to Level 1.
“L2” ------------------- Set Auto Picture Control to Level 2.
“OFF” ---------------- Set Auto Picture Control OFF.
“UP” ----------- The same operation as pressing Up key or Left key
“DN” -----------The same operation as pressing Down key or Right key
Details
Set Auto Picture Control (Available only in the normal Power ON status)
The value set by this command is not stored in the projector’s memory. Therefore,
when the power is turned to ALL OFF status, the value returns to the original
setting. (It is stored in Suspend mode.)
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]
8.4.8 CF_COLTEMP Command
Command
“CF_COLTEMP_%1” [CR]
%1
“000” – “003”
Details
Set Color Temperature (Available only in the normal Power ON status)
The value set by this command is not stored in the projector’s memory. Therefore,
when the power is turned to ALL OFF status, the value returns to the original
setting. (It is stored in Suspend mode.)
Acceptable
“000” [CR]
Response
Unacceptable