- 44 -
v
Video level adjustment
1
Receive the 16-step grey scale computer signal with
INPUT 2 [RGB]
mode.
2
Enter the service mode and select group no. “
200
”.
3
Connect an oscilloscope to test point “
TP_GVID1
” (+)
and chassis ground (-). Select item no. “
6
” and change
data value to adjust the amplitude to be
10.0
±0.05Vp-p.
4
Connect an oscilloscope to test point “
TP_RVID1
” (+)
and chassis ground (-). Select item no. “
7
” and change
data value to adjust the amplitude to be
10.0
±0.05Vp-p.
5
Connect an oscilloscope to test point “
TP_BVID1
” (+)
and chassis ground (-). Select item no. “
8
” and change
data value to adjust the amplitude to be
10.0
±0.05Vp-p.
(a)
black level
black level
b
Input adjustment
PC Input adjustment
1
Receive the 100% whole-white computer signal with
INPUT 2 [RGB]
mode.
2
Enter the service mode and select group no. “
784
”.
3
Select item no. “
0
” and change data value from “
0
” (de-
fault) to “
1
”. The adjustment will be carried out automati-
cally and the data value changes to “
2
” when finishing the
auto-adjustment correctly.
If the data value changes to “
-1
”, take adjustment above
again until the data is “2”.
AV Input adjustment
1
Receive the 100% whole-white component signal with
INPUT 2 [Y/Cr/Cb]
mode.
2
Enter the service mode and select group no. “
783
”.
3
Select item no. “
0
” and change data value from “
0
” (de-
fault) to “
1
”. The adjustment will be carried out automati-
cally and the data value changes to “
2
” when finishing the
auto-adjustment correctly.
If the data value changes to “
-1
”, take adjustment above
again until the data is “2”.
Electrical Adjustments
c
DC adjustment
1
Receive the 16-step grey scale computer signal with
INPUT 2 [RGB]
mode.
2
Enter the service mode and select group no. “
200
”.
3
Connect a digital voltmeter to test point “
TPV1G
” (+)
and chassis ground (-). Select item no. “
0
” and change
data value to adjust voltage to be
6.5
±0.1V.
4
Connect a digital voltmeter to test point “
TPV1R
” (+)
and chassis ground (-). Select item no. “
1
” and change
data value to adjust voltage to be
6.5
±0.1V.
5
Connect a digital voltmeter to test point “
TPV1B
” (+)
and chassis ground (-). Select item no. “
2
” and change
data value to adjust voltage to be
6.5
±0.1V.
6
Connect a digital voltmeter to test point “
TPV2G
” (+)
and chassis ground (-). Select item no. “
3
” and change
data value to adjust voltage to be
7.5
±0.1V.
7
Connect a digital voltmeter to test point “
TPV2R
” (+)
and chassis ground (-). Select item no. “
4
” and change
data value to adjust voltage to be
7.5
±0.1V.
8
Connect a digital voltmeter to test point “
TPV2B
” (+)
and chassis ground (-). Select item no. “
5
” and change
data value to adjust voltage to be
7.5
±0.1V.
Содержание PLC-EF60A
Страница 100: ... 100 IC Block Diagrams BA7078AF Sync Separator IC9033 L3E01031F0A RGB Level Shift IC3501 IC3521 IC3541 ...
Страница 101: ... 101 IC Block Diagrams LB1641 Motor Driver IC1601 IC1611 IC1621 IC1631 TB1274AF RGB Matrix IC3101 ...
Страница 102: ... 102 IC Block Diagrams TC4052BFT Selector IC9005 TC90A69F PAL Y C Separator IC2101 ...
Страница 103: ... 103 IC Block Diagrams TE7780 I O Expander IC4801 IC4802 MAS1390 G Sensor IC5711 ...
Страница 104: ... 104 IC Block Diagrams ...
Страница 149: ...KJ6 EF60A00 149 Mechanical Parts List 149 A B M02 1 M02 Lens Mount M02 4 M02 4 M02 3 M02 2 Lens Mount Ass y M02 3 ...
Страница 151: ...KJ6 EF60A00 151 Mechanical Parts List Optical Filter UV IR Mirrors L12 Optical Filter UV IR L11 Mirror Cold ...
Страница 153: ...KJ6 EF60A00 153 Mechanical Parts List L15 R G Optical Filter WV Optical Filter WV S05 S05 ...
Страница 154: ...KJ6 EF60A00 154 Mechanical Parts List 1 2 0 5 L03 Integrator In Integrator In ...
Страница 155: ...KJ6 EF60A00 155 Mechanical Parts List 1 2 0 5 L02 PBS L04 Integrator Out Integartor Out PBS S05 S05 ...
Страница 156: ...KJ6 EF60A00 156 Mechanical Parts List L09 Mirror R Mirror R S05 S05 ...
Страница 157: ...KJ6 EF60A00 157 Mechanical Parts List 157 Relay lens Out L08 Relay Lens Out ...
Страница 160: ... KJ6A Feb 2006 BB 400 Printed in Japan SANYO Electric Co Ltd ...
Страница 184: ...Diagrams Drawings KJ6 EF60A00 ...