PDG-DXL100 Basic Serial Command Specifications
18 / 19
Even if the temperature comes down during this process, the given Cooling Down process
is executed and it moves to Standby mode.
・
“21” [CR]
Status: Cooling Down in process after turned off due to lamp failure
When a projector is turned off because of lamp failure, it automatically starts Cooling Down
operation, in which the projector returns “21” [CR].
7.5
Input Mode Read Command
COMMAND
“CR1” [CR]
Detail
Get currently selected Input
Response
Acceptable
“%1” [CR]
%1
“1” = Selected. HDMI
“2” = Selected. Computer 1
“3” = Selected. YPbPr 1
“4” = Selected. Scart
“5” = Selected. Computer 2
“6” = Selected. YPbPr 2
“7” = Selected. Video
“8” = Selected. S-video
Unacceptable “?” [CR]
7.6
Lamp Time Read Command
COMMAND
“CR3” [CR]
Detail
Get total lamp running hours
Response
Acceptable
“%1” [CR]
%1, %2
Each lamp data follows in sequence with one space between
each of them.
%1 = lamp No.1
e.g.; “00410” [CR]
▪▪▪▪
→
Lamp No.1 = 410 Hours
Unacceptable “?” [CR]
7.7
Setting Read Command
COMMAND
“CR4” [CR]
Detail
Get screen setting status of Ceiling/Rear.
Response
Acceptable
“%1” [CR]
%1
“11” [CR] = Normal Screen Setting(Status: Desktop Front)
“10” [CR] = Picture is top/bottom reversed
(Status: Ceiling Rear)
“01” [CR] = Picture is left/right reversed (Status: Desktop Rear)
“00” [CR] = Picture is top/bottom and left/right reversed
(Status: Ceiling Front
)
Unacceptable “?” [CR]