– 27 –
5. AWB Adjustment
Preparation:
POWER switch: ON
Adjusting method:
1. When setting the camera in place, set it to an angle so that
nothing appears in any part of the color viewer except the
white section. (Do not enter any light.)
2. Double-click on the DscCalDi126a.
3. Click the AWB, and click the Yes.
4. AWB adjustment value will appear on the screen.
5. Click the OK.
6. Lens Adjustment
Preparation:
POWER switch: ON
Adjustment condition:
More than A3 size siemens star chart
Fluorescent light illumination with no flicker
Illumination above the subject should be 400 lux
±
10 %.
Adjustment method:
1. Set the siemens star chart 100 cm
±
3 cm so that it be-
comes center of the screen.
2. Double-click on the DscCalDi126a.
3. Click the Focus, and click the Yes.
4. Lens adjustment value will appear on the screen.
5. Click the OK.
7. CCD Defect Detect Adjustment
Preparation:
POWER switch: ON (Set the camera mode.)
Adjustment method:
1. Double-click on the DscCalDi126a.
2. Select “CCD Defect” on the LCD “Test”, and click the “Yes”.
3. After the adjustment is completed, OK will display.
4. Click the OK.
8. LCD Panel Adjustment
[CA3 board (Side A)]
8-1. LCD H AFC Adjustment
Preparation:
POWER switch: ON
Adjusting method:
1. Double-click on the DscCalDi126a.
2. Select 0 on the LCD “H AFC”.
3. While watching the LCD monitor, adjust VR171 so that the
edge of the LCD adjustment frame are the same distance
from the left and right edge of the LCD screen. (A = B)
8-2. LCD RGB Offset Adjustment
Adjusting method:
1. Adjust LCD “RGB offset” so that the amplitude of the CL416
waveform is 7.3 V
±
0.3 Vp-p.
LCD
adjustment
frame
A
B
LCD screen
FPC
VR171
CL415
CL414
CL416
Cable
Camera
Approx.
100 cm ± 3 cm
Siemens
star chart
Cable
Camera
0 - 18 cm
All white pattern
Color viewer (5,100K)