MAINTENANCE 

 

Some maintenance is recommended 
to maintain optimal output 
performance of the solar modules.  

 

If the module surface becomes dirty, 
it may reduce output power.  

  It is recommended to clean the 

surface of the module with water and 
a soft cloth or sponge.  

 

To remove persistent dirt, the module 
can be washed with a micro-fiber 
cloth and ethanol. 

 

Alternatively, a mild detergent may be 
used. Never use abrasive detergent, 
strong alkaline detergent and strong 
acid detergent to clean any part of the 
module. 

 

It is also recommended to inspect the 
electrical and mechanical connections 
annually. 

 

If you need electrical or mechanical 
inspection

 

or

 

maintenance, 

 

it

 

is 

recommended to have a licensed 
authorized professional carry out the 
inspection or maintenance to avoid 
the hazards of electric shock or injury. 

 

The return of any modules will not be 
accepted by SANYO unless prior 
written authorization has been given 
by SANYO. 

 

As part of our policy of continuous 
improvement SANYO reserves the 
right to change product specifications 
at any time without prior notice.  

 

For further information, please visit

 

www.sanyo-solar.eu

 or 

www.sanyo.com

 or contact a SANYO 

Authorized Representative.

 

 
© 20

1

1 Sep. SANYO Electric Co., Ltd.   

All Rights Reserved   9/6/2011 

Содержание HIT-H250E01

Страница 1: ...damage to the module Do not puncture or damage the back sheet of a module to avoid the hazard of electric shock and fire To avoid the hazard of electric shock and injury children and unauthorized persons should not be allowed near the installation of PV modules To avoid the hazard of electric shock and injury be sure to completely ground all modules To avoid the hazard of electric shock fire and i...

Страница 2: ...Representative with questions regarding mounting profiles for modules if needed Notes on Installation Clearance of 10 cm between the roof surface and module frame is required to allow cooling air to circulate around the back of the module This also allows any condensation or moisture to dissipate Install modules so that air can circulate between the roof and the module We recommend installation me...

Страница 3: ...des If these modules are connected each other incorrectly the bypass diodes cable or junction box may be damaged Array Wiring The term array is used to describe the assembly of several modules on a support structure with associated wiring Use copper wire that is sunlight resistant and is insulated to withstand the maximum possible system open circuit voltage Check your local codes for requirements...

Страница 4: ...ine detergent and strong acid detergent to clean any part of the module It is also recommended to inspect the electrical and mechanical connections annually If you need electrical or mechanical inspection or maintenance it is recommended to have a licensed authorized professional carry out the inspection or maintenance to avoid the hazards of electric shock or injury The return of any modules will...

Страница 5: ...pe HIT HIT HIT Maximum System Voltage Voc V 1000 1000 1000 Maximum over current protection rating A 15 15 15 Factory Installed Bypass Diodes 3 3 3 HIT Hetero junction with Intrinsic Thin layer Mechanical Specifications Model HIT H250E01 HIT H250E02 HIT H245E01 HIT H245E02 HIT H240E01 HIT H240E02 Length mm Width mm Height mm Weight kg 16 5 Electrical Specifications 861 1610 35 Figure 2 1 Dimensions...

Страница 6: ...r less Dimension in mm Figure 2 3 Optional Mounting Range Note Fixing span is 1050mm or less Optional Mounting Range P V U B 5 0 2 Figure 3 Configuration of Junction box Negative Positive Cable Connector MC Plug Figure 4 Number of series cells per bypass diode 1 st Block 96cells diode 3 rd Block 96cells diode 2 nd Block 48cells diode ...

Отзывы: