Sanyo HIP-215NKHE5 Скачать руководство пользователя страница 4

General Installation Manual 
 

• 

If  you  need  electrical  or  mechanical 
inspection

 

or

 

maintenance, 

 

it

 

is  recommended  to  have  a  licensed 
authorized  professional  carry  out  the 
inspection  or  maintenance  to  avoid 
the hazards of electric shock or injury. 

• 

The return of any modules will not be 
accepted  by  SANYO  unless  prior 
written  authorization  has  been  given 
by SANYO. 

• 

As  part  of  our  policy  of  continuous 
improvement  SANYO  reserves  the 
right to change product specifications 
at any time without prior notice.  

 
For  further  information,  please  visit

 

  

 

www.sanyo-solar.eu 

or 

www.sanyo.com  or  contact  a  SANYO 
Authorized Representative.
 
 
© 2008 Nov. SANYO Electric Co., Ltd.   
All Rights Reserved   17/11/08

Содержание HIP-215NKHE5

Страница 1: ...le to avoid the hazard of injury and damage to the module Do not puncture or damage the back sheet of a module to avoid the hazard of electric shock and fire To avoid the hazard of electric shock and injury children and unauthorized persons should not be allowed near the installation of PV modules To avoid the hazard of electric shock and injury be sure to completely ground all modules To avoid th...

Страница 2: ... and use of PV modules Operating Conditions SANYO recommends that modules be operated within the following Operating Conditions An installation location with conditions beyond the Operating Conditions or with other Special Conditions see below should be avoided Operating Conditions of SANYO modules are as follows 1 The modules should be operated only in terrestrial applications No space or other S...

Страница 3: ...maximum possible system open circuit voltage Check your local codes for requirements Earth Ground Wiring The kind of the earth construction shall conform to IEC61730 1 Bonding shall be by a positive means such as clamping riveting bolted or screwed connections or welding soldering or brazing The bonding connections shall penetrate all non conductive coatings such as paint anodized coatings or vitr...

Страница 4: ...injury The return of any modules will not be accepted by SANYO unless prior written authorization has been given by SANYO As part of our policy of continuous improvement SANYO reserves the right to change product specifications at any time without prior notice For further information please visit www sanyo solar eu or www sanyo com or contact a SANYO Authorized Representative 2008 Nov SANYO Electr...

Страница 5: ...1 5 57 5 54 5 50 Cell Type HIT HIT HIT HIT Maximum System Voltage Voc V 1000 1000 1000 1000 Maximum over current protection rating A 15 15 15 15 Factory Installed Bypass Diodes 3 3 3 3 HIT Hetero junction with Intrinsic Thin layer Mechanical Specifications Model HIP 215NKHE5 HIP 215NKHE5 2 HIP 210NKHE5 HIP 210NKHE5 2 HIP 205NKHE5 HIP 205NKHE5 2 HIP 200NKHE5 HIP 200NKHE5 2 Length mm Width mm Height...

Страница 6: ...mm Optional Mounting Range Dimension in mm Optional Mounting Range Note Fixing span is 1040mm or less Note Fixing span is 1040mm or less Figure 2 2 Optional Mounting Range Figure 2 3 Optional Mounting Range Figure 3 Configuration of Junction Box ...

Отзывы: