General Installation Manual 
 

• 

Follow  all  safety  precautions  of  other 
system components used. 

 
Installation 
General 

• 

Please  read  this  guide  completely 
before  installation  or  use  of  the 
modules. 

This 

section 

contains 

electrical 

and 

mechanical 

specifications  needed  before  using 
your SANYO PV modules. 

• 

Modules  should  be  firmly  fixed  in 
place  in  a  manner  suitable  to 
withstand 

all 

expected 

loads, 

including wind and snow loads.  

• 

The  drilling  and  addition  of  ground 
holes  is  permitted,  but  should  be 
avoided  whenever  possible  to  avoid 
damage  to  the  module.    When 
additional 

ground 

holes 

are 

necessary,  they  must  not  penetrate 
the inner side of the aluminum frame. 
Caution 

is 

advised 

to 

avoid 

accidentally  drilling,  scratching,  or 
penetrating the back sheet surface of 
the  module.    If  required,  it  is 
recommended 

to 

add 

additional 

ground  holes  to  the  outer  aluminum 
lip area of the module.  In such case, 
additional  ground  holes  must  be  at 
least  65  mm

 

away  from  any  frame 

corner. 

• 

For a non-integral module or panel, a 
statement  that  the  assembly  is  to  be 
mounted  over  a  fire  resistant  roof 
covering rated for the application. 

• 

Appropriate  material  should  be  used 
for mounting hardware  to  prevent the 
module  frame,  mounting  structure, 
and hardware itself from corrosion.  

• 

Install  modules  where  they  are  not 
shaded  by  obstacles  like  buildings 
and trees.  Especially pay attention to 
avoid  partially  shading  the  modules 
by objects during the daytime.  

• 

Please 

contact 

your 

SANYO 

Authorized 

Representative 

with 

questions regarding mounting profiles 
for modules if needed. 

 
Notes on Installation  

• 

Clearance  between  the  roof  surface 
and module frame is required to allow 
cooling  air  to  circulate  around  the 
back  of  the  module.  This  also  allows 
any  condensation  or  moisture  to 
dissipate.    Install  modules  so  that  air 
can  circulate  between  the  roof  and 
the module.  

• 

We  recommend  installation  methods 
shown  in  Figure  1.  In  some  areas, 
local electrical  codes may govern the 
installation and use of PV modules. 

 
Operating Conditions 
SANYO  recommends  that  modules  be 
operated  within  the  following  Operating 
Conditions.  An  installation  location  with 

conditions 

beyond 

the 

Operating 

Conditions 

or 

with 

other 

Special 

Conditions (see below) should be avoided.  
Operating  Conditions  of  SANYO  modules 
are as follows: 
1)  The modules should be operated only 

in terrestrial applications. No space or 
other Special Conditions (see below). 

2)  The  ambient  temperature  should  be 

within –20°C (-4°F) to 40°C (104°F).  

3)  The relative humidity should be within 

45% to 95%. 

4)  The

 

wind  pressure  load  of  the 

installation  site  should  be  less  than  
2,400N/m

2

 (50PSF). 

 
Special Conditions 
1)  The 

ambient 

temperature 

and 

installation  place  are  different  from 
the 

recommended 

Operating 

Conditions. 

2)  Salt  damage  is  severe  at  the 

installation place. 

3)  Hail  and  snow  damage  is  excessive 

at the installation place. 

4)  Sand  and  dust  damage  is  excessive 

at the installation place. 

5)  Air 

pollution, 

chemically 

active 

vapors, acid rain, and/or soot, etc. are 

excessive at the installation place.   

 
Specifications 
Notes on Specifications 
1)  Rated  electrical  characteristics  are 

within 10% of the values measured at 
Standard  Test  Conditions  (STC). 
Irradiance  of  1000W/m

2

,  25

o

C  cell 

temperature, 

and 

solar 

spectral 

irradiance per IEC 60904-3. 

2)  Under 

normal 

conditions, 

a   

photovoltaic  module  may  experience   
conditions  that  produce  more  current   
and/or  voltage  than  reported  at    
standard  component  test  conditions.  
Accordingly,  the  values  of  Isc  and 
Voc should   be multiplied by a factor 
of  1.25  when        determining  voltage 
ratings,  conductor  capacities,  fuse 
sizes,  and  size  of  controls connected 
to the module output.   

3)  The  current  output  for  the  modules 

shown 

in 

the 

Specifications 

is    

measured 

at 

Standard 

Test 

Conditions.    These  conditions  may 
not  be  frequently  observed  in  actual 
practice. 

 
 

 

Figure 1 : Installation

 

Solar Module

 

A

 

Installation (reference) – HIP-xxxNKHE5, xxxNKHE5-2

 

For questions regarding mounting profiles for modules, please contact your local dealer.

 

Solar Module

 

Mounting  
Structure Rail

 

Module

 

Mounting Structure Rail

 

M6 Bolt

 

Spring washer

 

M6 Nut

 

Flat washer

 

Flat washer

 

A

 

Spring washer

 

Section A-A 

Содержание HIP-215NKHE5

Страница 1: ...le to avoid the hazard of injury and damage to the module Do not puncture or damage the back sheet of a module to avoid the hazard of electric shock and fire To avoid the hazard of electric shock and injury children and unauthorized persons should not be allowed near the installation of PV modules To avoid the hazard of electric shock and injury be sure to completely ground all modules To avoid th...

Страница 2: ... and use of PV modules Operating Conditions SANYO recommends that modules be operated within the following Operating Conditions An installation location with conditions beyond the Operating Conditions or with other Special Conditions see below should be avoided Operating Conditions of SANYO modules are as follows 1 The modules should be operated only in terrestrial applications No space or other S...

Страница 3: ...maximum possible system open circuit voltage Check your local codes for requirements Earth Ground Wiring The kind of the earth construction shall conform to IEC61730 1 Bonding shall be by a positive means such as clamping riveting bolted or screwed connections or welding soldering or brazing The bonding connections shall penetrate all non conductive coatings such as paint anodized coatings or vitr...

Страница 4: ...injury The return of any modules will not be accepted by SANYO unless prior written authorization has been given by SANYO As part of our policy of continuous improvement SANYO reserves the right to change product specifications at any time without prior notice For further information please visit www sanyo solar eu or www sanyo com or contact a SANYO Authorized Representative 2008 Nov SANYO Electr...

Страница 5: ...1 5 57 5 54 5 50 Cell Type HIT HIT HIT HIT Maximum System Voltage Voc V 1000 1000 1000 1000 Maximum over current protection rating A 15 15 15 15 Factory Installed Bypass Diodes 3 3 3 3 HIT Hetero junction with Intrinsic Thin layer Mechanical Specifications Model HIP 215NKHE5 HIP 215NKHE5 2 HIP 210NKHE5 HIP 210NKHE5 2 HIP 205NKHE5 HIP 205NKHE5 2 HIP 200NKHE5 HIP 200NKHE5 2 Length mm Width mm Height...

Страница 6: ...mm Optional Mounting Range Dimension in mm Optional Mounting Range Note Fixing span is 1040mm or less Note Fixing span is 1040mm or less Figure 2 2 Optional Mounting Range Figure 2 3 Optional Mounting Range Figure 3 Configuration of Junction Box ...

Отзывы: