Troubled
portion
MANU
LED
SPEED
LED
WIDTH
LED
T
roubled phenomenon
Check item
Counteraction method
POWER
○
○
○
○
○
○
●
○
○
○
○
REMOTE
CONTROL
●
●
●
●
●○
○
○
○
○
○
○
MASSAGE
MOTOR
●
●
●
●
●
○
○
○
○
●
○
T
APPING
MOTOR
●
●
●
●
●○
○
○
○
○
●
○
1. Check the current fuse for fusion.
2. Check the Printed board (Main) CN1 output (AC100V).
3. Check the Printed board (Main) CN9 output (AC100V).
4. Check the power transformer output CN10 (approx. 12V).
5. Check the Printed board (main) CN11 for connector come-off.
6. Check the Printed board (remote control) CN601 for connector
come-off.
7. Check the remote control cable for disconnection or shorting.
1. Check the Printed board (main) CN11 for connector come-off.
2. Check the Printed board (remote control) CN601 for connector
come-off.
3. Check the remote control cable for disconnection or shorting.
1.
The connection confirmation of Printed board (main) CN6 and the junction connector
.
2.
Check the Printed board (main) CN6 output (approx. DC60 - 100V).
3.
The connection confirmation of Printed board (main) CN13 and Printed board (relay) CN201.
4.
The connection confirmation of Printed board (Shape) CN501 and CN503.
5.
Check the Printed board (UP/DOW Pulse) IC201 and IC202 for inclination.
6. The magnet check for the MOMI detection.
1.
The connection confirmation of Printed board (main) CN8 and the junction connector
.
2.
Check the Printed board (main) CN8 output (approx. DC60 - 100V).
3. Check the belt (
TAT
AKI) for dislocation and cut-off.
4.
The connection confirmation of Printed board (main) CN13 and Printed board (relay) CN201 and CN202.
5. The connection confirmation of Printed board (pulse) CN301.
6. Check the Printed board (pulse) IC301 for inclination.
7. The magnet check for the
TAT
AKI detection.
・
Replace the current fuse.
・
Check the power switch and power cord and transfomer for
normal conductivity and replace them if necessary upon check.
・
Replace the Printed board (main).
・
Replace the power transformer
.
Insert the connector
.
・
Replace the remote control cable.
Insert the connector
.
・
Replace the remote control cable.
Insert the connector
.
If output Replace the massage motor
.
If no output Replace the Printed board (main).
Insert the connector
.
Insert the connector
.
Correct the tilted condition or replace the Printed board (relay).
The magnet position correction for the detection.
Insert the connector
.
If output Replace the tapping motor
.
If no output Replace the Printed board (main).
The tapping motor belt correction, the exchange.
Insert the connector
.
Insert the connector
.
Correct the tilted condition or replace the Printed board (Pulse).
The magnet position correction for the detection.
Nothing is displayed after the
power ON.
Trouble described is displayed
immediately or 3 seconds after
the power switch is turned ON.
The rubdown motor doesn't move.
It displays 15 seconds later
after rubdown choice.
Massaging mode remains
unchanged.
The tapping motor doesn't move.
It displays 15 seconds later
after rubdown choice.
Tapping mode remains
unchanged.
- 9 -
Problem Diagnosis Chart
HEC-DR21
(TAIWAN)