- 10 -
THERMISTOR CHART
Thermistor connector
Duct
Magnetron
7. DISASSEMBLY INSTRUCTIONS
- THE OVEN MUST BE DISCONNECTED FROM THE
ELECTRICAL OUTLET WHEN MAKING REPLACE-
MENTS, REPAIRS, ADJUSTMENT OR CONTINUITY
CHECKS. BEFORE PROCEEDING WITH ANY RE-
PAIR, WORK , WAIT AT LEAST 1 MINUTE, UNTIL
THE CAPACITOR IN THE HIGH VOLTAGE AREA HAS
FULLY DISCHARGED.
A. REMOVING INTERLOCK MONITOR SWITCH
(See Figure 1 on page 1)
(1) Disconnect all lead wires from the interlock moni-
tor switches.
(2)Remove 2 screw securing the lever stopper.
(3)Pull out the interlock monitor toward you while
pressing switch stopper.
(4) Make the necessary adjustment, and perform a
microwave energy leakage check according to
“ 1 . A D J U S T M E N T P R O C E D U R E F O R
SWITCHES” on page 1. Check proper operation
according to “CHECKOUT PROCEDURE FOR
SWITCHES” on page 7.
B.REMOVING DOOR INTERLOCK SWITCH
(See Figure on page 1)
(1) Disconnect all lead wires from the door inter-
lock switch .
(2) Remove 2 screw secutring the lever stopper.
(3) Pull out the door interlock switch toward you
while pressing switch stopper.
(4) Make the necessary adjustments or replace-
ment of the switch by reversing step (3) and
check microwave energy leakage according to
“ 1 . A D J U S T M E N T P R O C E D U R E F O R
SWITCHES” on page 1. Check proper operation
according to “CHECKOUT PROCEDURE FOR
SWITCHES” on page 7.