![Sanyo DP39843 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/sanyo/dp39843/dp39843_installation-manual_363283010.webp)
~
~
GND
(+)
(–)
RED
A
B
✱
✱
WHITE
(GRAY/B
(BLAC
(GND
(GND
(BLU
(GND
Connections 1
9
Monitor Connection
• Using different cables from
those specified here may
attenuate the video and/or sync
signals and interfere with
correct transmission.
• RG-59U coaxial cables can be
used when distance between
devices is short, but not in duct
or aerial routing.
Cable type
Length
RG-59U (3C-2V)
250 m (273 yds) max.
RG-6U (5C-2V)
500 m (547 yds) max.
RG-11U (7C-2V)
600 m (656 yds) max.
Note:
All connection cables should be 24 AWG or
higher with a maximum length of no more than
600 m (656 yds).
Coaxial cable
b
With AC 24 V
Power Supply Connection
b
With DC 12 V
Check that +/- polarity is correct.
✱
For the connections, use AWG (20, 21, 22)
cables.
1
Push and hold the lever a, and
then insert the cable into the
terminal hole
B
.
2
Release the lever
A
.
BNC type
Digital video recorder etc.
Shielded LAN cable
(CAT5 or higher, straight type)
See “Connection when Using PoE
Power Supply” or “Connection when
Not Using PoE Power Supply”.
L5CE2_CD2_XE(INSTALLATION).book 9 ページ 2008年4月16日 水曜日 午後3時18分