-13-
Service Adjustments with Replacing Memory IC(IC802)
No.
Item
Range
Data
Description
185
R MATRIX PAL
0 ~ 3
1
R Matrix 50
186
R MATRIX NT DEFFER
0 ~ 3
1
R matrix gain control for YCbCr (NTSC Offset)
187
WHITE BALANCE
0 ~ 3
........
WHITE BALANCE (R-Drive & B-Drive)
188
CUT OFF ( R )
0 ~ FF
0
R OUT Pedestal level adjustment ( R Bias for White balance )
189
CUT OFF ( G )
0 ~ FF
0
G OUT Pedestal level adjustment ( G Bias for White balance )
190
CUT OFF ( B )
0 ~ FF
0
B OUT Pedestal level adjustment ( B Bias for White balance )
191
CUT OFF
.........
One Line
192
FAST SW
0 ~ 1
0
193
E/W P 50 ZOOM
0 ~ 3F
0
EW_PARA_50_ZOOM
194
E/W C UP 50 ZOOM
0 ~ 3F
0
EW_COR_U_50_ZOMM
195
E/W C LOW 50 ZOOM
0 ~ 3F
0
EW_COR_L_50_ZOMM
196
E/W T 50 ZOOM
0 ~ 3F
0
EW_TRAPE_50_ZOOM
197
E/W H SIZE 50 ZOOM
0 ~ 3F
0
EW_HSIZE_50_ZOOM
198
E/W P 60 ZOOM
0 ~ 3F
0
EW_PARA_60_ZOOM
199
E/W C UP 60 ZOOM
0 ~ 3F
0
EW_COR_U_60_ZOOM
200
E/W C LOW 60 ZOOM
0 ~ 3F
0
EW_COR_L_60_ZOOM
201
E/W T 60 ZOOM
0 ~ 3F
0
EW_TRAPE_60_ZOOM
202
E/W H SIZE 60 ZOOM
0 ~ 3F
0
EW_HSIZE_60_ZOOM
203
E/W P 50 WIDE
0 ~ 3F
0
EW_PARA_50_WIDE
204
E/W C UP 50 WIDE
0 ~ 3F
0
EW_COR_U_50_WIDE
205
E/W C LOW 50 WIDE
0 ~ 3F
0
EW_COR_L_50_WIDE
206
E/W T 50 WIDE
0 ~ 3F
0
EW_TRAPE_50_WIDE
207
E/W H SIZE 50 WIDE
0 ~ 3F
0
EW_HSIZE_50_WIDE
208
E/W P 60 WIDE
0 ~ 3F
0
EW_PARA_60_WIDE
209
E/W C UP 60 WIDE
0 ~ 3F
0
EW_COR_U_60_WIDE
210
E/W C LOW 60 WIDE
0 ~ 3F
0
EW_COR_L_60_WIDE
211
E/W T 60 WIDE
0 ~ 3F
0
EW_TRAPE_60_WIDE
212
E/W H SIZE 60 WIDE
0 ~ 3F
0
EW_HSIZE_60_WIDE
213
OPT MONO STE
0 ~ 1
0
Option Stereo / Mono (0=Stereo w/ surround; 1=Mono w/o surround)
214
OPT VOL TABLE
0 ~ 1
0
Option Volume Table
215
OPT MPP
0 ~ 1
1
Option MPP (0=with MPP; 1=without MPP)
216
OPT BOOSTER
0 ~ 1
1
Option Booster (0=with Booster; 1=without Booster)
217
OPT AV SEL
0 ~ 3
0
Option Audio Video Select
218
OPT COL SYSTEM
0 ~ 2
1
Option Color System
219
OPT SIF SYSTEM
0 ~ 3
1
Option SIF System (0=Auto/BG/I/DK/m, 1=BG/I/DK, 2=S-1/S-2, 3=M Fixed)
220
OPT LG ALPS TCL
0 ~ 2
0
Option Maker Tunner LG , ALPS , TCL
221
OPT PLUG & PLAY
0 ~ 1
0
Option Plug and Play
222
OPT ASIA ME HSE
0 ~ 2
1
Option ASIA Middle East HSE
223
POWER ON TIME
0 ~ FF
0
Power ON Timer
224
OSD H - POSITION
0 ~ FF
3F
OSD Horizontal Position
225
OSD V - ( 60 Hz )
0 ~ FF
16
OSD Vertical NTSc
226
VOLUME OFFSET
0 ~ 7
0
Volume Offset
227
BASS OFFSET
0 ~ 7
0
BASS OFFSET
228
TREBLE OFFSET
0 ~ 7
0
TREBLE OFFSET
229
OPT AFT
0 ~ 1
1
0 : For VCO AFT Voltage 2.5 V (WS 1.2) ==> 1 : for (WS 2.0)
230
OPT CHMUTE
0 ~ 1
1
VIDEO MUTE WHEN changing posion 0: NO MUTE 1: MUTE
Following table shows the initial values which have been stored in the CPU ROM, and items for the service adjustments.
Service mode adjustments table in CPU ROM
SM_21-BE6V (AC7-A)AUS 5/9/08 11:11 AM Page 13
Содержание CP21SE1K
Страница 35: ... 35 ...
Страница 36: ...SANYO Electric Co Ltd May 08 30 CPS Printed In Indonesia ...