3
WM – 700700
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
Rating conditions are:
Cooling: Outside air temperature 95°F DB/ 75°F WB
Indoor unit entering air temperature 80°F DB/67°F WB
Heating: Outside air temperature 47°F DB/ 43°F WB
Indoor unit entering air temperature 70°F WB
Model No.
KMH0922
Type
Wall-mounted
Cooling
Heating
Capacity
BTU/h
8,800 / 8,700
10,000 / 9,800
kW
2.58 / 2.55
2.93 / 2.87
Air circulation (High)
cu. ft./min.
220 / 210
Moisture removal (High)
pints/h
2.2
Phase, Frequency
Hz
Single, 60
Voltage rating
V
230 / 208
Available voltage range
V
187 to 253
Heat element
kW – HSPF
—
1.0 / 0.82 – 6.6 / 6.6
Controls
Microprocessor
Control unit
Remote control unit
Temperature control
IC thermostat
Timer
ON/OFF 12-hours
Fan speeds
3
Air deflector
Horizontal / Vertical
Manual / Manual
Air filter
Washable, easy access
Operation sound
Hi / Me / Lo
dB-A
40 / 35 / 30
Refrigerant tubing connections
Flare type
Refrigerant tube o.d.
Narrow tube
in. (mm)
1/4 (6.35)
Wide tube
in. (mm)
3/8 (9.52)
Refrigerant tube kit
Optional
Accessories
Mounting bracket
Height
in. (mm)
13-19/32 (345)
Width
in. (mm)
31-1/2 (800)
Depth
in. (mm)
7-3/32 (180)
Net weight
lbs. (kg)
24 (11)
Shipping volume
cu. ft. (cu. m)
3.3 (0.093)
Shipping weight
lbs. (kg)
29 (13)
Performance
Electrical
Rating
Features
Dimensions &
Weight
Applicable Indoor Unit
92-144 S/M (Basic) 00.12.13 10:32 AM ページ 3