Outdoor Unit :
CM2472A
Indoor Unit
:
KMS0972
×
3
Power Supply : 230V Single Phase 60Hz
< Cooling Capacity >
TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h)
1. Rating conditions (#) : Indoor Unit Entering Air Temp. 80 °F (26.7 °C) D.B. / 67 °F (19.4 °C) W.B.
: Outdoor Ambient Temp. 95 °F (35 °C) D.B.
2.
3. Above data represents the value when the operation frequency of a compressor is fixed.
Above data does not take Freeze Prevention Protection during cooling operation into account.
For this reason, the value may vary from the actual cooling characteristics.
NOTE
RATING CAPACITY: 25,400 BTU/h
AIR FLOW RATE:
883 CFM
INDOOR
OUTDOOR
ENT. TEMP. °F (°C)
AMBIENT TEMP. °F (°C)
W.B.
D.B.
65
75
85
95
105
115
(18.3)
(23.9)
(29.4)
(35.0)
(40.6)
(46.1)
TC
25,690
24,800
23,840
23,190
22,040
17,290
72 (22.2) SHC
20,210
19,870
19,360
19,010
18,500
16,440
59
76 (24.4) SHC
23,130
22,790
22,270
22,100
21,410
17,290
(15.0)
80 (26.7) SHC
25,690
24,800
23,840
23,190
22,040
17,290
84 (28.9) SHC
25,690
24,800
23,840
23,190
22,040
17,290
88 (31.1) SHC
25,690
24,800
23,840
23,190
22,040
17,290
TC
26,810
25,900
24,910
24,290
23,110
17,700
72 (22.2) SHC
16,790
16,440
15,930
15,760
15,240
13,010
63
76 (24.4) SHC
19,700
19,360
19,010
18,670
18,160
15,930
(17.2)
80 (26.7) SHC
22,960
22,440
22,100
21,760
21,240
17,700
84 (28.9) SHC
25,870
25,530
24,910
24,290
23,110
17,700
88 (31.1) SHC
26,810
25,900
24,910
24,290
23,110
17,700
TC
27,910
26,980
25,970
# 25,400
24,180
18,070
72 (22.2) SHC
13,360
13,010
12,500
12,330
11,810
9,590
67
76 (24.4) SHC
16,270
15,930
15,590
15,240
14,900
12,500
(19.4)
80 (26.7) SHC
19,360
19,010
18,670
18,330
17,990
15,590
84 (28.9) SHC
22,440
22,100
21,590
21,410
20,900
18,070
88 (31.1) SHC
25,360
25,020
24,670
24,330
23,810
18,070
TC
28,980
28,030
26,990
26,500
25,010
18,380
72 (22.2) SHC
9,590
9,240
8,900
8,730
8,210
5,980
71
76 (24.4) SHC
12,670
12,330
11,810
11,640
11,130
8,900
(21.7)
80 (26.7) SHC
15,760
15,410
15,070
14,730
14,210
11,990
84 (28.9) SHC
18,670
18,330
17,990
17,810
17,300
15,070
88 (31.1) SHC
21,590
21,240
20,900
20,730
20,210
17,990
TC
29,880
28,920
27,870
27,460
25,330
18,590
75
76 (24.4) SHC
9,070
8,730
8,390
8,210
7,530
5,470
(23.9)
80 (26.7) SHC
12,160
11,810
11,470
11,300
10,610
8,560
84 (28.9) SHC
15,070
14,730
14,390
14,390
13,700
11,640
88 (31.1) SHC
18,160
17,810
17,470
17,300
16,610
14,560
49