2. SPECIFICATIONS
2-1. Unit Specifications
Indoor Unit
KHS3082
Outdoor Unit
CH3082
< 230V >
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
Rating conditions are:
Cooling: Indoor air temperature 80°F D.B. / 67°F W.B.
Outdoor air temperature 95°F D.B. / 75°F W.B.
Heating: Indoor air temperature 70°F D.B.
Outdoor air temperature 47°F D.B. / 43°F W.B.
Vertical
dB-A
dB-A
Indoor : Hi/Me/Lo/Qt*
Outdoor : Hi
Air Filter
Compressor
Refrigerant / Amount charged at shipment
Ibs (g)
Refrigerant Control
( 14,000 to 33,000 )
( 4.1 to 9.7 )
16.5
3,290
( 5.0 to 16.5 )
( 1,000 to 3,290 )
15.3
3,070
( 4.5 to 15.3 )
( 900 to 3,070 )
30,600
9.0
33,000
9.7
( 10,900 to 30,600 )
( 3.2 to 9.0 )
Shipping Volume
Cooling
Heating
18,600
12,000
Net
Shipping
Package Dimensions
Weight
Height
×
Width
×
Depth
Height
×
Width
×
Depth
Ibs (kg)
Ibs (kg)
cu.ft (m
3
)
(mm)
inch
(mm)
230V Single-Phase 60Hz
inch
-
-
187 to 253
Dimensions
&
Weight
(*Qt = Quiet mode)
Refrigerant Tubing Connections
Unit Dimensions
Operation Sound
Electrical
Rating
Sensible Capacity
Latent Capacity
W
Power Input
V
A
Available Voltage Range
Running Amperes
Refrigerant Tube Kit / Accessories
Narrow tube
Wide tube
Refrigerant
inch (mm)
Tube Diameter
inch (mm)
32.0
39.7
4.59
(14.5)
(18.0)
(0.13)
185.2
207.2
15.88
(84.0)
(94.0)
(0.45)
42-3/8
×
40
×
16-3/8
(1,076
×
1,016
×
416)
(300
×
1,065
×
230)
(910
×
940
×
340)
12-7/32
×
44-7/8
×
14-31/32
(310
×
1,140
×
380)
Outdoor Unit
Indoor Unit
11-13/16
×
41-15/16
×
9-1/16
35-13/16
×
37-1/32
×
13-3/8
3/8 (9.52)
5/8 (15.88)
ft (m)
Max. allowable tubing length at shipment
Flare Type
164 (50)
49 / 44 / 39 / 32
49 / 44 / 39 / 32
55
55
R410A / 6.5 (2,950)
Electric Expansion Valve
Washable, Anti-Mold
DC Twin Rotary (Inverter)
Manual
Auto
Timer
Indoor / Outdoor
Fan Speeds
24-Hour ON or OFF Timer, 1-Hour OFF Timer
Auto and 3 steps / Auto (Hi, Me, Lo)
Airflow Direction (Indoor)
Horizontal
Controls / Temperature Control
Control Unit
Microprocessor / I.C. Thermister
Wireless Remote Control Unit
Features
HSPF
Compressor Locked Rotor Amperes
BTU/Wh
Optional / Air Clean Filter
BTU/h
Performance
-
9.0
%
Power Factor
87
87
A
31.0
Voltage Rating
BTU/h
kW
Total Capacity
BTU/h
SEER
BTU/Wh
16.0
-
630 (1,070)
671 (1,140)
Air Circulation (High)
ft
3
/min (m
3
/h)
9.57
-
Moisture Removal (High)
Pints/h
COP
W/W
-
3.15
EER
BTU/h/W
9.30
-
Fuse or Circuit Breaker Capacity
A
35
7