To unmount indoor unit
Press the 2
▲
▲
marks on the lower part of the indoor
unit and unlatch the tabs. Then lift the indoor unit and
unmount. (Fig. 38)
3-10. Drain Hose
a)
The drain hose should be slanted downward to the
outdoors. (Fig. 39)
b)
Never form a trap in the course of the hose.
c)
If the drain hose will run in the room, insulate the
hose with insulation
*
so that chilled condensation
will not damage furniture or floors. (Fig. 40)
*
Foamed polyethylene or its equivalent is recom-
mended.
WARNING
Risk of Electric Shock
Do not supply power to the
unit or operate it until all
tubing and wiring to the
outside unit are completed.
;;
;;
;;
;;;;
;;;;
;;;;
;;
;;
;;
Condensation
Insulation material
(locally purchased)
must be used.
Fig. 40
Push
Fig. 38
;;
;;
;;
;;;;
;;;;
;;;;
Slant
Drain
hose
Indoor
unit
Fig. 39