Special Remarks
‘‘DRY’’ ( ) Operation
How it works?
•
Once the room temperature reaches the level that was set, the unit
repeats the cycle of turning on and off automatically.
•
During DRY operation, the fan speed is automatically set to LOW or
VERY LOW; the fan speed then switches back and forth between LOW
(for 20 seconds) and VERY LOW (for 10 seconds).
•
‘‘DRY’’ operation is not possible if the indoor temperature is 59 °F or
less.
Heating ( ) Operation
Heating performance
•
This air conditioner is a refrigerant heating type unit which uses
combustion gas to heat the refrigerant heater during heating operation.
The heating capacity is unaffected depending on the outdoor
temperature. However, if sufficient heat cannot be obtained with this air
conditioner, use another heating appliance in conjunction with it.
Power failure
during operation
•
In the event of power failure, the unit will stop. When the power is
turned on again, the unit restarts within three minutes.
Clicking Sound
Clicking sound is
heard from the air
conditioner
•
In heating or cooling operation, any plastic parts may expand or shrink
due to a sudden temperature change. In this event, a clicking sound
may occur. This is normal, and the sound will soon disappear.
Remote Control Unit
•
The remote control unit sends the setting condition to the air
conditioner regularly at three minute intervals.
20
OI-202-20EG
oi202000