31
8-2. Cooling
8-2-1. Room Temperature Control
●
Room temperature control is obtained by cycling the compressor ON and OFF under control of the room
temperature sensor in the indoor unit.
●
All information is transmitted every 3 minutes by the remote control unit to the controller in the indoor unit.
●
The control circuit will not attempt to turn the compressor ON until the compressor has been OFF for at
least 3 minutes. To protect the compressor from stalling out when trying to start against the high side
refrigerant pressure, the control circuit has a built-in automatic time delay to allow the internal pressure to
equalize.
●
As a protective measure, the control circuit switches the compressor OFF after 3 minutes or more of com-
pressor operation.
●
Thermo. ON:
When the room temperature is above T°F (T°F is set temperature).
Compressor
➔
ON
●
Thermo. OFF: When the room temperature is equal to or below set temperature T – 1°F.
Compressor
➔
OFF
3 minutes
3 minutes
3 minutes
Set temp.
T
°
F
T – 1
°
F
Compressor
More than
3 minutes
Set speed
OFF
OFF
OFF
OFF
Outdoor fan
Indoor fan
Thermo.
OFF
Thermo.
ON
Thermo.
OFF
Thermo.
ON