-8-
C2WVV
SERVICE ADJUSTMENTS
[After replacing the Memory IC (IC803)]
The memory IC, IC803, stores the service adjustments data for each circuit, therefore, when the memory IC is
replaced, it should be performed “OPTION SETTING” on previous page and the following adjustments, refer to
further adjustment on page 14.
ADJUSTABLE SERVICE ADJUSTMENT
REGULAR
WIDE
To enter to the Service Mode
+ Press and hold the GREEN button on the remote control and then press the P
▼
button inside of the door. The
adjustment window will appear on the screen.
REGULAR
WIDE
OTHERS
TB1251
ADJUST
OK
SELECT:
EXIT : RECALL
IMPORTANT NOTICE
Do not attempt to adjust service adjustments not listed on the above otherwise it may cause
loss of performance and product safety.
Item No.
OSD
Description
1
P V-P
Vertical Centre Adjustment
2
P H-P
Horizontal Centre Adjustment
5
P V-S
Vertical Size Adjustment
6
P H-S
Horizontal Size Adjustment
7
P PCC
Pcc Adjustment
8
P TRP
Trapezoid Distortion Adjustment
10
P CNR
Corner Adjustment
Item No.
OSD
Description
1
AGC
AGC Adjustment
2
CUT
Cut-Off Drive Adjustment
3
GRY
G-Drive Adjustment
4
GRY
B-Drive Adjustment
7
HBP
H-Blanking Phase Adjustment
8
OSD
OSD Positioning Adjustment
Note: Some items of the service adjustments for this chassis are controlled by the CPU, IC801, and the
adjustments are carried out by using the RC handset.