COMPONENT
CHECKOUT PROCEDURE
RESULT
Measure the resistance : Across two terminals
Normal reading :
with an Ohm-Meter on highest scale.
Momentarily indicates several Ohms,
and gradually returns to 10 Meg-Ohms.
HIGH-VOLTAGE
Abnormal reading :
CAPACITOR
Indicates continuity or 10 Meg-Ohms
including
from the beginning.
BLEEDER
RESISTOR
Measure the resistance : Across two terminals
Normal reading :
with an Ohm-Meter on R x 10,000 scale.
Indicates about the middle position in
one direction (forward direction) and
infinite Ohms in the reverse direction,
using meter which is provided with a
9 volt battery.
HIGH-VOLTAGE
DIODE
NOTE
--Some digital meter may show over
even in a forward direction because
low measuring voltage of meter does
not allow the meter current to pass
through the High Voltage Diode.
Abnormal reading :
Indicates continuity or infinite Ohms
in both directions.
- 5 -
Figure 7
Ohm-Meter
Figure 8
Ohm-Meter