- 10 -
H. REMOVING CAVITY COVER
(Figure 13)
(1) Gently press both ends to release 3 hooks,
while holding the Cavity Cover from the
inside of oven.
(2) Pull out the Cavity Cover.
I. REMOVING TURNTABLE MOTOR COVER
(Figure 14)
(1) Turn over the oven on its back.
(2) Cut the 6-joints of the Bottom Plate using
diagonal pliers (nipper).
(3) Separate the Motor Cover from Bottom Plate.
(4) Remove 2 screws securing Turntable Motor
to the Cavity and take it out.
NOTE
: Bent the cut joints inside slightly for
safety and be careful of sharp edge.
F. REMOVING DOOR
(1) Remove 2 hex nuts securing the upper hinge.
(2) Tilt the top of the Door toward you.
(3) Lift up the Door to remove it.
NOTE
-- After replacing the Door, be sure to check that
the Primary Interlock Switch, the Door Sensing
Switch and the Interlock Monitor Switch operate
normally. (See page 1).
-- After replacing the Door, check for microwave
energy leakage with a leakage detector.
Microwave energy leakage should be no greater
than 4mW/cm
2
to allow for measurement
uncertainty.
G. DISASSEMBLING DOOR
(Figure 12)
(1) Insert a thin flat-blade screwdriver between
the Choke Dielectric and the Door Main Frame
and lift up the Choke Dielectric to release
hooks one by one. (Figure 12).
(2) Remove the Choke Dielectric.
(3) To detach the Door Cover, insert a thin flat-blade
screwdriver between Door Cover and Door Panel
and release the projections inside Door Cover.
(4) To detach the Door Panel, insert a thin flat-blade
screwdriver between the Door Cover and Door
Main Frame.
NOTE
-- The Choke Dielectric may be damaged
when it is removed. When reinstalling
it replace it with new ones if it is damaged.
-- After installing the Door in place, check for
microwave energy leakage with a detector.
Microwave energy leakage should be no
greater than 4mW/cm
2
to allow for
measurement uncertainty.
Figure 14
Motor Cover
6 Joints
Bottom Plate
Cavity Cover
Figure 13
Press
Press
Hooks
Hooks
Hooks
Hooks
Door
Main
Frame
Choke
Dielectric
Figure 12