background image

UN Test Data         (Model:3UR18650-2-T0590)

1.Test Item: Altitude simulation (T1)

P.3/10

2.Test Purpose: This test simulates air transport under low-pressure conditions.
3.Test Procedure:
   Test cells and batteries shall be stored at a pressure of 11.6kPa or less  for at least  six hours at ambient 
   temperature(20±5

).

  SANYO Internal Procedure:
  As above.

4.Test Requirements:
   No mass loss(less than 0.1%),no leakage,no venting,no disassembly,no rupture and no fire,and the voltage 
   retention is not  less than 90%.
   The requirement relating to voltage is not applicable to test batteries at fully discharged states.
5.Test Date:         2007/10/11
6.Test Data

Before test After test

Before test After test

1

294.50

294.50

0.000

12.55

12.52

99.8

0

PASS

2

293.74

293.71

0.010

12.54

12.52

99.8

0

PASS

3

294.34

294.30

0.014

12.55

12.52

99.8

0

PASS

4

294.02

294.02

0.000

12.55

12.52

99.8

0

PASS

5

294.69

294.67

0.007

0

PASS

6

294.80

294.79

0.003

0

PASS

7

294.79

294.76

0.010

0

PASS

8

294.49

294.50

0.003

0

PASS

9

294.13

294.13

0.000

12.56

12.55

99.9

0

PASS

10

294.68

294.68

0.000

12.56

12.55

99.9

0

PASS

11

294.68

294.67

0.003

12.56

12.56

100.0

0

PASS

12

294.05

294.05

0.000

12.56

12.56

100.0

0

PASS

13

294.55

294.55

0.000

0

PASS

14

294.59

294.60

0.003

0

PASS

15

294.12

294.12

0.000

0

PASS

16

294.41

294.38

0.010

0

PASS

Notes: L-Leakage, V-Venting, D-Disassembly, R-Rupture, F-Fire,
       0-No leakage, no venting, no disassembly, no rupture & no fire

Voltage(V)

Voltage

Retention(

%)(=>90%)

Other
event

Result Judgement

 At first

cycle,in

fully

charged

states

PASS

At first

cycle,in

fully

discharged

states

After 50

cycles

ending in

fully

charged

states

After 50

cycles

ending in

fully

discharged

states

Battery No.

Mass(g)

Mass

loss (%)

(=<0.1%)

Содержание 3UR18650-2-T0950

Страница 1: ......

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ...10 12 54 12 52 99 8 0 PASS 3 294 34 294 30 0 014 12 55 12 52 99 8 0 PASS 4 294 02 294 02 0 000 12 55 12 52 99 8 0 PASS 5 294 69 294 67 0 007 0 PASS 6 294 80 294 79 0 003 0 PASS 7 294 79 294 76 0 010 0 PASS 8 294 49 294 50 0 003 0 PASS 9 294 13 294 13 0 000 12 56 12 55 99 9 0 PASS 10 294 68 294 68 0 000 12 56 12 55 99 9 0 PASS 11 294 68 294 67 0 003 12 56 12 56 100 0 0 PASS 12 294 05 294 05 0 000 1...

Страница 6: ...ement relating to voltage is not applicable to test batteries at fully discharged states 5 Test Date 2007 10 17 6 Test Data Before test After test Before test After test 1 294 50 294 43 0 024 12 52 12 36 98 7 0 PASS 2 293 71 293 65 0 020 12 52 12 36 98 7 0 PASS 3 294 30 294 27 0 010 12 52 12 36 98 7 0 PASS 4 294 02 293 91 0 037 12 52 12 35 98 6 0 PASS 5 294 67 294 60 0 024 0 PASS 6 294 79 294 71 0...

Страница 7: ... than 0 1 no leakage no venting no disassembly no rupture and no fire and the voltage retention is not less than 90 The requirement relating to voltage is not applicable to test batteries at fully discharged states 5 Test Date 2007 10 19 6 Test Data Before test After test Before test After test 1 294 43 294 49 0 020 12 36 12 35 99 9 0 PASS 2 293 65 293 69 0 014 12 36 12 35 99 9 0 PASS 3 294 27 294...

Страница 8: ...s less than 0 1 no leakage no venting no disassembly no rupture and no fire and the voltage retention is not less than 90 The requirement relating to voltage is not applicable to test batteries at fully discharged states 5 Test Date 2007 10 23 6 Test Data Before test After test Before test After test 1 294 49 294 45 0 014 12 35 12 35 100 0 0 PASS 2 293 69 293 67 0 007 12 35 12 34 99 9 0 PASS 3 294...

Страница 9: ...rs for the test to be concluded SANYO Internal Procedure As above 4 Test Requirements External temperature of test batteries does not exceed 170 and there is no disassembly no rupture and no fire within six hours of this test 5 Test Date 2007 10 25 6 Test Data 1 0 PASS 2 0 PASS 3 0 PASS 4 0 PASS 5 0 PASS 6 0 PASS 7 0 PASS 8 0 PASS 9 0 PASS 10 0 PASS 11 0 PASS 12 0 PASS 13 0 PASS 14 0 PASS 15 0 PAS...

Страница 10: ...to the impact Each sample is to be subjected to only a single impact Separate samples are to be used for each impact A coin or button cell is to be impacted with the flat surface of the sample parallel to the flat surface and the 15 8mm diameter curved surface lying across its center SANYO Internal Procedure As above 4 Test Requirements External temperature of test batteries does not exceed 170 C ...

Страница 11: ...ltage of the battery or 22V b when the manufacturer s recommended charge voltage is more than 18V the minimum voltage of the test shall be 1 2 times the maximum charge voltage Tests are to be conducted at ambient temperature The duration of the test shall be 24 hours SANYO Internal Procedure Min Charge Voltage 22 V Charge Current 6 44 A 4 Test Requirements There is no disassembly and no fire withi...

Страница 12: ...p orientation As above 4 Test Requirements A Package passes the test if it meets the following criteria Each package is capable of withstanding a 1 2 meter drop test in any orientation without damage to cells cell contact and without release of contents 5 Test Date 2009 11 18 6 Test Data PASS Drop height 1 2m 6 1 No any package crack 6 2 No any cell damege and battery damage 6 3 No any out side re...