background image

UN Test Data         (Model:3LUNA-1-T0636)

1.Test Item:

 External short circuit (T5)

P.7/10

2.Test Purpose:

 This test simulates an external short circuit.

3.Test Procedure:

  The cell or battery to be tested shall be temperature stabilized so that its external case temperature reaches

  55±2

 and then the cell or battery shall be subjected to a short circuit condition with a total external

  resistance of less than 0.1ohm at 55±2

.This short circuit condition is continued for at least one hour after

  the cell or battery external case temperature has returned to 55±2

. The cell or battery must be observed

  for a further six hours for the test to be concluded.

  SANYO Internal Procedure:

   As above.

4.Test Requirements:

  External temperature of test batteries does  not exceed 170

 and there is no disassembly,no rupture and

  no fire within six hours of this test.

5.Test Date:  

        2010/2/3-2010/2/3

6.Test Data

1

0

PASS

2

0

PASS

3

0

PASS

4

0

PASS

5

0

PASS

6

0

PASS

7

0

PASS

8

0

PASS

9

0

PASS

10

0

PASS

11

0

PASS

12

0

PASS

13

0

PASS

14

0

PASS

15

0

PASS

16

0

PASS

Notes: D-Disassembly, R-Rupture, F-Fire, 0-No disassembly, no rupture & no fire

After 50

cycles

ending in

fully

discharged

states

55.1

54.5

54.5

54.9

55.1

54.4

After 50

cycles

ending in

fully

charged

states

54.7

54.4

55.1

54.9

 At first
cycle,in

fully

charged

states

55.1

PASS

54.9

54.5

54.8

At first

cycle,in

fully

discharged

states

54.9

54.5

Battery No.

Maximum temperature (°C)

Other

event

Result

Judgement

Содержание 3LUNA-1-T0636

Страница 1: ...it Overcharged The sample has passed the items of UN38 3 Date March 30 2010 Sanyo Test Report Lithium Ion Battery 3LUNA 1 T0636 SANYO Energy Suzhou CO LTD SANYO Energy Suzhou CO LTD United Nations Recomenndations on the TRANSPORT OF DANGEROUS GOODS Remark Consignor Address Sanyo Energy Suzou Co Ltd Check Certification by Similar Model 3LUNA 1 T0636 Ratio of 3LUNA 1 T0636 3LUNA 1 T0636 100 100 Elec...

Страница 2: ...nt which is given influence The element which is given influence T1 Altitude Simulation Decompression load Crimped part Gasket Cell Gas Release Vent Cell Case Cell Pack Plastic Case Holding Member Insulator Insulation Tape Both Sides Tape Coating materials Date March 30 2010 B Checklist for Judging New Type Battery or not Confirmation of presence of change in The element which is given influence C...

Страница 3: ...ies First cycle 50 charged First cycle fully charged 4 batteries For cell only After 50 cycles fully discharged After 50 cycles fully charged 4 batteries 5 cells for cylindrical cell 10 cells for prismatic cell 10 cells for prismatic cell 5 cells for cylindrical cell 5 cells for coin cell 5 cells for coin cell Lithium equivalent content Manual of Tests and Criteria ST SG AC 10 11 Rev 4 PartIII sub...

Страница 4: ...long side 4 flat on the short side 5 on a corner We declare the above The test result mentioned above was checked according to UN test Model Regulations ST SG AC 10 1 Rev 15 Special Provision188 Lithium equivalent content 1 98 g AL10A31 Mar 30 2010 Nominal voltage Watt hour rating Lithium ion battery Specification Customer Model E1004342 Sanyo Product Code Sanyo Model F12431008 3LUNA 1 T0636 Certi...

Страница 5: ...37 12 83 12 81 99 8 0 PASS 3 161 84 161 81 0 019 12 82 12 81 99 9 0 PASS 4 162 31 162 32 0 006 12 85 12 83 99 8 0 PASS 5 162 01 161 97 0 025 0 PASS 6 162 01 161 98 0 019 PASS 7 161 99 161 96 0 019 0 PASS 8 161 93 161 92 0 006 0 PASS 9 162 03 162 04 0 006 12 83 12 82 99 9 0 PASS 10 161 81 161 84 0 019 12 85 12 84 99 9 0 PASS 11 161 99 162 04 0 031 12 83 12 82 99 9 0 PASS 12 161 87 161 90 0 019 12 8...

Страница 6: ...relating to voltage is not applicable to test batteries at fully discharged states 5 Test Date 2010 1 26 2010 2 2 6 Test Data Before test After test Before test After test 1 162 00 161 95 0 031 12 82 12 62 98 4 0 PASS 2 161 93 161 92 0 006 12 81 12 61 98 4 0 PASS 3 161 81 161 77 0 025 12 81 12 60 98 4 0 PASS 4 162 32 162 25 0 043 12 83 12 62 98 4 0 PASS 5 161 97 161 95 0 012 0 PASS 6 161 98 161 96...

Страница 7: ...an 0 1 no leakage no venting no disassembly no rupture and no fire and the voltage retention is not less than 90 The requirement relating to voltage is not applicable to test batteries at fully discharged states 5 Test Date 2010 2 2 6 Test Data Before test After test Before test After test 1 161 95 161 96 0 006 12 62 12 62 100 0 0 PASS 2 161 92 161 95 0 019 12 61 12 60 99 9 0 PASS 3 161 77 161 78 ...

Страница 8: ... less than 0 1 no leakage no venting no disassembly no rupture and no fire and the voltage retention is not less than 90 The requirement relating to voltage is not applicable to test batteries at fully discharged states 5 Test Date 2010 2 3 6 Test Data Before test After test Before test After test 1 161 96 161 95 0 006 12 62 12 62 100 0 0 PASS 2 161 95 161 93 0 012 12 60 12 60 100 0 0 PASS 3 161 7...

Страница 9: ...r the test to be concluded SANYO Internal Procedure As above 4 Test Requirements External temperature of test batteries does not exceed 170 and there is no disassembly no rupture and no fire within six hours of this test 5 Test Date 2010 2 3 2010 2 3 6 Test Data 1 0 PASS 2 0 PASS 3 0 PASS 4 0 PASS 5 0 PASS 6 0 PASS 7 0 PASS 8 0 PASS 9 0 PASS 10 0 PASS 11 0 PASS 12 0 PASS 13 0 PASS 14 0 PASS 15 0 P...

Страница 10: ...sides will be subjected to the impact Each sample is to be subjected to only a single impact Separate samples are to be used for each impact A coin or button cell is to be impacted with the flat surface of the sample parallel to the flat surface and the 15 8mm diameter curved surface lying across its center SANYO Internal Procedure As above 4 Test Requirements External temperature of test batterie...

Страница 11: ...e of the battery or 22V b when the manufacturer s recommended charge voltage is more than 18V the minimum voltage of the test shall be 1 2 times the maximum charge voltage Tests are to be conducted at ambient temperature The duration of the test shall be 24 hours SANYO Internal Procedure Min Charge Voltage Charge Current 4 Test Requirements There is no disassembly and no fire within seven days of ...

Страница 12: ...op of five orientations with one sample if the packing does not have the big damage Drop orientation As above 4 Test Requirements A Package passes the test if it meets the following criteria Each package is capable of withstanding a 1 2 meter drop test in any orientation without damage to cells cell contact and without release of contents 5 Test Date 2010 2 4 6 Test Data PASS Drop height 1 2m Insi...

Отзывы: