— 16 —
5-4-3 Diode test ( )
Resistance
measurement
Continuity check
Diode test
Selection
Cathode
Anode
Good: Forward voltage
drop shown
Bad: 0.000 V shown
OL shown
Good: OL shown
Bad: Other indication
Remarks:
The open voltage
between the
measuring terminals
is equal to: Power
supply voltage –
Approx. 0.2 V.
Forward
direction test
Reverse
direction test
Remarks:
s
For capacitance measurement in the
11 nF and 110 nF ranges, press the
button to cancel the indi-
cated value before connecting the
capacitor to be measured and then
perform the measurement.
s
The indication may not become stable due
to influence of surrounding noises or stray
capacitance of the test leads.
5-5 Capacitance Measurement ( )
Cancel
indicated
value prior to
measurement
Never apply a voltage to the measuring terminals.
WARNING
1. Remove electric charge in the capacitor prior to measurement.
2. Because this meter applies a current to the capacitor to measure,
it is not suitable for measurement of electrolytic capacitors having
a large leak current as a large error may occur.
3. For capacitors having large capacitance, measurement takes a longer time.
CAUTION
Function
Max. Rated Input
Range
CAP ( )
110.00 mF
11.000 nF, 110.00 nF, 1.1000 μF, 11.000 μF,
110.00 μF, 1.1000 mF, 11.000 mF, 110.00 mF