25
How to Use Each Feature
How to Use Each Feature
●
Fail Safe Operation is a feature to keep the servos in a predetermined position for each channel in the
event that the receiver cannot receive a signal from the transmitter. A feature to keep the servos in a
predetermined position for the servo of the throttle channel (2ch) in the event that the battery voltage on
the receiver side of an engine RC car goes below the set voltage is Battery Fail Safe Operation.
●
Battery Fail Safe Operation cannot be set when the throttle channel (2ch) is set to FREE/HOLD (*Battery
Fail Safe Operation works only for the throttle channel).
*Don't use Battery Fail Safe Operation feature for electric RC cars.
1) Select F/S with the multi-selector and select a channel to set
fail safe operation (ST/TH/AUX1/AUX2) with the select button.
2) Enter the set channel and operate the multi-selector.
The fail safe mode setting changes in order of
FREE
→
FS
→
HOLD.
○
Setting Range: FREE/FS(-100
~
100%)/HOLD
○
Default: FREE
FREE (Free Mode)
When thre receiver cannot receive the signal from the transmitter, the signal output to the servo stops and
the servo will be free.
FS (Fail Safe Mode)
When the receiver cannot receive the signal from the transmitter, the servo will be held in the set position.
HOLD(Hold Mode)
The last postion before the signal from the transmitter to the receiver is lost will be held.
*When using with Gyro, please set HOLD. In case of FREE, the Gyro might be able to be misworking.
*
When the receiver can receive the signal from the transmitter again, each mode of FREE/HOLD/FS is
automatically released.
3) Setting the Fail Safe (FS)
Move to the position where the Fail Safe Operation is used. When the position is determined, long press
the Enter key to set the position when the Fail Safe Operation works.
*For safety reason, we recommend setting the throttle channel on the brake side when setting the Fail
Safe.
4) Setting the Battery Fail Safe Operation
After setting the throttle channel position, move the cursor to [B-F/S] to set the voltage.
○
Setting Range: OFF, 3.5v
~
7.4v
*The Battery Fail Safe Operation is a feature to activate
Fail Safe Operation when the receiver battery voltage belows
to the set voltage on a Nitro car.
Don't use the Battery Fail Safe feature on electric RC cars.
5) Checking the Fail Safe Operation
Turn off the power of the receiver while the Fail Safe Operation
is set and check if the servo moves to the position where
the Fail Safe Operation is set.
Setting F/S
Setting F/S
F/S Setting Position
BATT-F/S Setting
• About the Fail Safe Operation
When the Fail Safe feature is on, check the setting of the Fail Safe before operating.
Don't change the setting of the Fail Safe during operation.
IMPORTANT
FAIL SAFE [F/S]
SETTING
Содержание MT-5