5
2. Take the reflector off by removing the 4
screws that hold it to the ballast box and
remove the lamp connector from the lamp
3. Using an ohmmeter place 1 probe on 1 of the
4 pins and by sensing the 3 remaining pins, 1
should have continuity. Make sure the 2
remaining pins also have continuity.
5.3 By-pass circuit board (test ballast and UV lamp together)
Step
1. Open the SRMax ballast box
Refer to instructions above
2. Unplug from the circuit board the line
(black) from the power cord. See picture to the
left.
Insert black wire from the power cord into
connector identified “Bypass”. See picture to
the right.
3. Place the unit on the ground and make sure
that you don’t have direct line of sight with the
lamp. Plug the power cord directly in a power
outlet and the UV lamp will light up if both the
UV lamp and ballast are still functional.