Chapter 6. Profile
39
▶
vl velocity deceleration (Object: 0x6049)
It is the Object that sets Deceleration Time.
As shown in the picture as below, it determines acceleration time
through Delta Speed and Delta Time.
In consideration of the stability of our inverter, it fixes Delta Speed at
Max Speed.
Index
Sub-
index
Name
Type Property Unit
Range
0x6049
VI velocity deceleration
-
-
-
-
0
Number of
entries
U8
RO
-
-
2
Delta Time
U16
RO
sec
0.0~600.0
▶
vl velocity Quick Stop (Object: 0x604A)
It is the object that sets Quick Stop time.
As shown in the picture as below, it determines Quick Stop
Deceleration Time through Delta Speed and Delta Time.
In consideration of the stability of the inverter, it fixes Delta Speed at
the maximum speed,
Time
Delta
Speed
Delta
velocity
Vl
on
decelerati
Delta Time
Delta
Speed
Time
Ve
lo
cit
y
Transfer characteristic of the velocity deceleration
Time
Delta
Speed
Delta
q
elocity
Vl
stop
uick
v
Delta Time
Delta
Speed
Time
Ve
lo
cit
y
Transfer characteristic of the quick stop