Santerno 4600TL Скачать руководство пользователя страница 13

QUICK START GUIDE

 

 

SUNWAY M XS 

 

11/26

 

EN
G

L

ISH
 

INSTALLATION 

 

DANGER 

 

Always remove voltage before operating on the grid. The ground conductor must be connected first. 
 

 

CAUTION 

Follow the sequence below to carry out the electrical connection of the SUNWAY M XS: 

1.  Carry out the ground connection of the inverter; 

2.  Carry out the electrical connection to the grid; 

3.  Carry out the electrical connection of the inverter to the photovoltaic field. 

 

RESIDUAL CURRENT DEVICE  –  A residual current device is integrated into the Sunway M XS. The RCD provides 
protection against residual DC and AC currents and is compliant with the safety regulations in force. The efficiency of the 
RCD is checked when testing the inverter and whenever the inverter is connected to the grid.  The integrated RCD 
provides protection against DC-side faults only. As per AC-side protection, an external RCD of type A is to be provided to 
protect the line between the inverter and the delivery point. 

MOULDED CASE CIRCUIT BREAKER – Always install a MCCB to protect the electric circuit. 

 
Carry out the ground connection of the  inverter before carrying out any electrical connection. The SUNWAY M XS is 
supplied with a three-wire cable for the connection to the grid. First connect the yellow-green wire to the ground of the 
electrical system external to the inverter. The yellow-green wire is internally connected to the Protective Earth of the 
circuit. Please consult the Installation and Programming Guide for any details on how to assemble the quick connectors 
for the connection to the PV field. 
 
The Sunway M XS inverters are supplied from the grid. Once the connection to the grid is complete, press the WAKE UP 
button to start up the inverter. 

If the DC disconnect switch (optional) is installed, it must be set to ON. 
 
Carry out the quick configuration procedure from the Settings menu by pressing the icon here below.  The quick 
configuration procedure makes it possible to change the grid interface settings as well.  Note that the grid interface 
configuration may be changed only within the first 12 hours after the commissioning of the inverter. 

 

When the quick configuration procedure is complete, press START to start up the inverter. 
The inverter checks if the field voltage is higher than the value set in P020 (factory setting: 370V)  and waits for the 
timeout in P021 (factory-setting: 5 minutes) before connecting in parallel with the grid and start delivering power.  
 

   CAUTION 

 

GRID INTERFACE CONFIGURATION –  The grid interface configuration based on the Country where the inverter is 
installed may be changed only within the first 12 hours after the commissioning of the inverter. 

PASSWORD FORM –  The password  required  to access the inverter data is given in a special form supplied with the 
SUNWAY M XS inverter. Please consult the Installation and Programming Guide for any details about the inverter 
functionality. 

 

 

Содержание 4600TL

Страница 1: ...E SOLAR INVERTER Guida Rapida Quick Start Guide Guide Rapide Schnelle Installationsanleitung Gu a R pida 14 03 2012 R 03 Elettronica Santerno S p A Strada Statale Selice 47 40026 Imola BO Italy Tel 39...

Страница 2: ...SUNWAY M XS 4600 TL 5000 TL 6000 TL 7500 TL...

Страница 3: ...NZIONE Non connettere tensioni di alimentazione superiori alla nominale In caso venga applicata una tensione superiore alla nominale possono verificarsi guasti ai circuiti interni In caso di applicazi...

Страница 4: ...ambienti salini Altitudine Fino a 2000m s l m Per altitudini comprese tra i 2000m s l m e i 3000m s l m declassare dell 1 la corrente di uscita ogni 100 m Per altitudini superiori consultare Elettroni...

Страница 5: ...e MPPT dell inverter Vdc 330 740 Tensione massima campo fotovoltaico Vdc 845 Corrente massima di ingresso del generatore fotovoltaico A 15 5 17 20 25 Categoria di sovratensione e tensione di tenuta al...

Страница 6: ...ttorno all apparecchiatura misure in mm ATTENZIONE Evitare di montare il SUNWAY M XS esposto all azione diretta della radiazione solare o al di sopra di fonti di calore DIAGRAMMA DI CONNESSIONE ON OFF...

Страница 7: ...connesso alla terra dell impianto esterno all inverter Effettuare in seguito l allacciamento alla rete elettrica e al campo fotovoltaico Per dettagli sull assemblaggio dei connettori a innesto rapido...

Страница 8: ...st l inverter varia automaticamente la soglia di scatto della grandezza che si intende verificare fino a quando non interviene la protezione al raggiungimento del valore misurato permettendo cos di ve...

Страница 9: ...xplosion risks and fire hazard CAUTION Do not connect supply voltages exceeding the equipment rated voltage to avoid damaging the internal circuits If the equipment is installed in environments contai...

Страница 10: ...kling or dripping do not install in salty environments Altitude Up to 2000m a s l For altitudes ranging from 2000m to 3000m a s l derate the output current by 1 every 100m For higher altitudes please...

Страница 11: ...9000 MPPT voltage Vdc of the inverter 330 740 Max voltage Vdc of the PV field 845 Maximum current A of the photovoltaic generator 15 5 17 20 25 Overvoltage category and impulse withstand voltage kV II...

Страница 12: ...er for the free circulation of air through the equipment clearance is expressed in mm CAUTION Do not expose the SUNWAY M XS to direct solar radiation or to heat sources WIRING DIAGRAM ON OFF DISCONNEC...

Страница 13: ...reen wire is internally connected to the Protective Earth of the circuit Please consult the Installation and Programming Guide for any details on how to assemble the quick connectors for the connectio...

Страница 14: ...s la tension nominale L application d une tension sup rieure la tension nominale peut provoquer des d faillances des circuits internes En cas d installation dans des milieux avec pr sence de substance...

Страница 15: ...intements d eau en des milieux salins Altitude Jusqu 2000m au dessus du niveau de la mer Pour des altitudes comprises entre 2000m et 3000m d tarez de 1 le courant de sortie tous les 100m Pour des alti...

Страница 16: ...MPPT de l onduleur Vcc 330 740 Tension maximum du champ PV Vcc 845 Courant maximum d entr e du g n rateur PV A 15 5 17 20 25 Cat gorie de surtension et niveaux de tension de tenue aux impulsions kV II...

Страница 17: ...ts autour de l appareillage mesures en mm ATTENTION Ne montez pas le SUNWAY M XS expos directement au rayonnement solaire ou au dessus de sources de chaleur SCH MA DE RACCORDEMENT ON OFF DISCONNECTING...

Страница 18: ...eurs Sunway M XS sont aliment s par le r seau lectrique Une fois que le raccordement au r seau lectrique a t effectu appuyez sur le bouton WAKE UP pour la mise en marche de l onduleur Si le sectionneu...

Страница 19: ...alls eine h here Spannung als die Nennspannung angelegt wird k nnen Sch den an den internen Schaltkreisen auftreten Bei der Anwendung in R umlichkeiten in denen Brennstoffe und oder explosive Stoffe v...

Страница 20: ...en sein Nicht in einer Umgebung mit stark salzhaltiger Luft einbauen H he Bis zu 2000 m d M Bei H hen zwischen 2000 und 3000 m d M muss der Ausgangsstrom alle 100 m um 1 deklassiert werden Im Falle vo...

Страница 21: ...enerators Wp 5500 6000 7000 9000 MPPT Spannung des Wechselrichters Vdc 330 740 Maximale Leistung des photovoltaischen Felds Vdc 845 Maximaler Eingangsstrom des Photovoltaik Generators A 15 5 17 20 25...

Страница 22: ...er Abbildung gezeigten freien R ume um das Ger t mm ACHTUNG Bei der Montage darf SUNWAY M XS nicht der direkten Sonnenstrahlung ausgesetzt oder ber W rmequellen positioniert werden ANSCHLUSSSCHEMA ON...

Страница 23: ...lage au erhalb des Wechselrichters angeschlossen wird Danach muss der Anschluss an das Stromnetz und an das photovoltaische Feld ausgef hrt werden F r Details ber den Einbau der Schnellanschlussverbin...

Страница 24: ...No conecte tensiones de alimentaci n superiores a la nominal Si se aplica una tensi n superior a la nominal pueden ocurrir aver as en los circuitos internos Si se aplica en ambientes con posible prese...

Страница 25: ...en ambientes salinos Altitud Hasta 2000m s n m En caso de altitudes incluidas entre 2000m s n m y 3000m s n m desclase del 1 la corriente de salida cada 100m En caso de altitudes superiores consulte a...

Страница 26: ...ensi n MPPT del inversor Vcc 330 740 Tensi n m xima campo fotovoltaico Vcc 845 Corriente m xima de entrada del generador fotovoltaico A 15 5 17 20 25 Categor a de sobretensi n y tensi n soportada a lo...

Страница 27: ...la figura alrededor del equipo medidas en mm CUIDADO Evite montar el SUNWAY M XS con exposici n a la acci n directa de la radiaci n solar o encima de fuentes de calor DIAGRAMA DE CONEXI N ON OFF DISC...

Страница 28: ...A continuaci n efect e la conexi n a la red el ctrica y al campo fotovoltaico Para m s detalles relativos al montaje de los conectores de conexi n r pida utilizados para conectar el campo fotovoltaic...

Отзывы: