Included components
8m and 10m
pole heights
1x – wooden drill template
INSTALLATION PROCEDURE FOR ANCHOR BOLTS:
1. Prepare footing as required by local codes.
2. Install anchor hooks, hex nuts, washers and wooden template as shown in Fig 3.
Level template in all directions.
Note
: template thickness is less than base plate
thickness. Dimensions given account for the difference.
3. After footing has properly cured, remove wooden template. Do not remove lower
hex nuts or washers.
Included: hardware is galvanized
8m and 10m pole
: (4) anchor bolts, 1”-8 UNC x 36” x 4” hook,
(8) heavy hex nuts, 1”-8 UNC, (8) flat washers, 1.06” ID x 2.00” OD x 0.15” thick
Landscape Forms is not responsible for site preparation and footings. The following
chart gives necessary information for calculating proper footing size, depending on
the specified light pole.
WARNING!
Pole mounted luminaires must be attached either before or
immediately
after pole installation. Failure to do so may cause vibration damage to the pole and
will void the pole warranty.
7” diameter base pole
Fig. 2 – Base plate orientation
to luminaire
Pole Size
Base Overturning
Moment (ft-lbf)
Base Shear
(lbf)
7"x.188“/5”x.250”x8m
11,682
567
8"x.250“/5”x.250”x8m
20,161
761
Tools Required
•
Safety glasses
•
Wrenches, 1-5/8” for 8m (5in/7in) pole
•
Level
Fig.3- Anchor install detail
LIGHTING LAYOUT RECOMMENDATIONS:
Refer to the product data sheet available at
for
recommendations for light pole spacing.
Installation Guide
Candela
Area Light Anchor Kit and Pole
www.landscapeforms.com Ph: 800.521.2546
Date: December 17, 2019
Page 1 of 2
Fig. 1 – Sidewalk setback
HANDHOLE ORIENTED
ON SIDE OPPOSITE
OF LUMINAIRE
SETBACK
SIDEWALK
8” diameter base pole
4 PLACES
CONDUIT
OPENING