TV/AV
-
VOL
+
MENU
MENU
VOLUME -
CHANNEL UP
CHANNEL DOWN
S1.00110111 S2.01111000
ADDRESS DATA
02
H-PHA 16
Item No.
Item
Data value
General
This set has an On-screen Service Menu system included in the CPU that allows remote operation for most of the
service adjustments.
2. Service Adjustments:
Press the CHANNEL UP/DOWN button on the remote
control handset to select the desired service menu
item you want to adjust.
Use the / - button to adjust the data. The
+ or - button will increase or decrease the data
sequentially.
3. Exit from the Service Menu
Press the MENU button to turn off the Service Menu
display.
The data which is set in the service mode is stored
into the memory IC automatically.
[ Service Mode Display ]
Service Adjustment-1
1. Enter the Service Menu
While pressing the MENU button on the television, press the Number Key 2 on the remote control unit.
The Service Menu now appear.
IC802 (EEPROM) Replacement
When IC802 (EEPROM) is replaced, IC801 (CPU) will automatically write the initial reference data into IC802 for basic TV operation.
However, the bus data should be checked and some bus data should be set up before attempting the service adjustments. (See
pages 9 ~ 12 for detailed information.)
Initial Bus Data Setup
Note: When IC802 (EEPROM) is replaced, following Service Menu should be set up for proper TV operation before attempting the
service adjustments.
NO.01 RFAGC (Adjust the data 11 to 14)
NO.23 EWCBM (Adjust the data 08 to 11) NO.87 ZOMCON (Adjust the data -6 to -8)
NO.02 H-PHA (Adjust the data 10 to 14)
NO.27 EWTLN (Adjust the data -4 to -1)
NO.121 POMT (Adjust the data 05 to 12)
NO.05 V-SCO (Adjust the data 16 to 23)
NO.28 EWCTPN (Adjust the data -3 to -1) NO.125 CCD (Adjust the data 20 to 30)
NO.06 V-LIN (Adjust the data 30 to 28)
NO.29 EWCBN (Adjust the data -5 to -2)
NO.09 V-S60 (Adjust the data -1 to -3)
NO.11 VLI60 (Adjust the data +1 to 0)
NO.43 B-YD (Adjust the data 08 to 09)
NO.129 EWCTPZ (Adjust the data +1 to +5)
NO.17 OSDHP (Adjust the data 30 to 40) NO.53 RBAG (Adjust the data 08 to 09)
NO.18 OSDC (Adjust the data 18 to 30)
NO.56 RBAGN (Adjust the data -2 to 0)
NO.19 EWDC (Adjust the data 44 to 35)
NO.58 RBDN (Adjust the data -2 to -5)
NO.20 EWAMP (Adjust the data 16 to 19) NO.60 RBBDN (Adjust the data 03 to 00)
NO.21 EWTL (Adjust the data 28 to 30)
NO.61 COGV (Adjust the data 00 to 03)
NO.22 EWCTP (Adjust the data 07 to 09) NO.62 BLKS (Adjust the data 01 to 00)
Service Adjustments
-8-
Содержание TS5129T
Страница 31: ...Mar 05...