Parameter
Description
PEAK
WELD
(Current)
This parameter sets the PEAK weld current when in
PULSE
mode
This parameter sets the TIG WELD current in
STD
,
SLOPE
,
REPEAT
and
SPOT
modes when
PULSE
is off. This parameter also sets the STICK
weld current.
BASE
(Background
Current)
This parameter sets the Background current when in Pulse TIG mode.
SPOT TIME
This parameter sets the duration of the
SPOT TIME
in
HF TIG
mode only
WIDTH
(Pulse)
This parameter sets the percentage on time of the
PULSE FREQUENCY
for PEAK weld current when the
PULSE
is on.
FREQ.
(Pulse)
This parameter sets the
PULSE FREQUENCY
when the
PULSE
is on.
DOWN SLOPE
This parameter operates in TIG modes only and is used to set the time for
the weld current to ramp down, after the torch trigger switch has been
pressed, to
CRATER CUR.
This control is used to eliminate the crater that
can form at the completion of a weld.
CRATER CUR.
This parameter operates in
SLOPE
or
REPEAT
(4T) TIG modes only and
is used to set the finish current for TIG. The CRATER Current remains on
until the torch trigger switch is released after it has been depressed.
POST-FLOW
This parameter operates in TIG modes only and is used to adjust the post
gas flow time once the arc has extinguished. This control is used to
dramatically reduce oxidation of the tungsten electrode.
SAVE/LOAD
The SAVE/LOAD buttons are used to save and retrieve a total number of 5
programs into the 160P memory.
SAVE the Current Weld Parameters into Memory
•
Press the
SAVE
button
•
Select a memory location by rotating the control knob, 1 to 5 is displayed
on the meter.
•
After selecting the desired memory location (ie 1 to 5), press the right
scroll button and the machine will give a beep to confirm the weld
parameters from the control panel are saved.
LOAD (retrieve) a Program to Control Panel
•
Press the
LOAD
button.
•
Select a memory location by rotating the control knob, 1 to 5 is displayed
on the meter.
After selecting the desired memory location (ie 1 to 5), press the right scroll
button and the machine will give a beep to confirm the weld parameters are
loaded onto the control panel.
Содержание SANARG 160P
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 15: ...15 1 3 2 GRAPHIC SYMBOL LEGEND ...
Страница 24: ...24 PAGE LEFT INTENTIONALLY BLANK ...
Страница 35: ...35 Figure 3 1 Electrical Input Connections 160P ...
Страница 47: ...47 PAGE LEFT INTENTIONALLY BLANK ...
Страница 55: ...55 6 4 4 SPOT MODE Contactor Hot start Iw ON ON HF Solenoid Output current ON Preflowtime Hot cur Spot time ...
Страница 64: ...64 PAGE LEFT INTENTIONALL BLA ...
Страница 76: ...76 10 1 INTERCONNECT DIAGRAM 160P ...
Страница 77: ...77 ...
Страница 78: ...78 10 2 EXPLODED VIEW COMPONENT LAYOUT 160P ...
Страница 79: ...79 ...
Страница 80: ...80 PAGE LEFT INTENTIONALL BLANK ...
Страница 81: ...81 10 3 EXPLODED VIEW WIRING LAYOUT 160P ...