Sanosil Q-Jet Superior
37
7. Troubleshooting
To determine and search for anomalies it is essential to have this Operation and Maintenance Manual at hand.
7.1 Table
Anomaly
Possible Cause
Remedy
Device does not work / does not
respond
•
Check power supply
•
Check fuses
•
Check correct insertion of cable
•
Ensure power supply to device
Fan does not work
•
Thermal motor sensor stops engine
(too high engine temperature)
•
Air-intake filter too dirty
•
Check engine, switch off and on
•
Set-up device once more
•
Clean or change filter
Liquid is not sprayed
•
Tank is empty
•
Nozzle is clogged
•
Fill liquid
•
Remove obstruction
Device does not start or stops
before finishing program
•
Cycle has been terminated abnormally
(e.g. power cuts)
•
Switch off and on again
•
Set-up device once more
Device emits loud noises
•
Possible internal damages
•
Presence of foreign bodies in the fan
•
Switch off and unplug
device, call service
technician
Device leaks liquid
•
Possible internal damages
•
Internal piping rupture or connections
leaking
•
Device was tipped on its side without
completely empty.
•
Switch off and unplug
device, open device and
remove water. Let device
completely dry. If device
still leaks call service
technician