Page 19
5.1 Battery charger
High performance is achieved by 2-step automatic und digital control engineering. This
allows for quick charging in the first step, then compensation/trickle charging in the
second step. It is possible to check the condition of the battery.
With LCD display und revolving mains plug.
5.1.1 Testing
Connect the battery charger with the battery (without plugging into the mains)
After approximately 9 seconds the test result is displayed (off-load voltage of the
battery)
100% - full
Battery is operational
80 %
50%
20%
Charge the battery
0% - flat
5.1.2 Charging
1.
Connect the charging unit to the battery
2.
The off-load voltage of the battery is shown on the display
3.
Plug the charging unit into the mains
4.
The charging operation begins
The present charge status of the battery is symbolized by progress bars:
full, 100 %
approx. 80 %
approx. 50 %
flat, 0-20 %