- 5 -
When there is a deviation between the actual size value and the
expected measurement value, you can click the input deviation value to
correct.You can also click
to correct it
。
Such as:The measured workpiece size is
φ
50.0
(
+0.02
),
The theoretical
value of standard parts is
φ
50.01
,
Because of manufacturing deviation,The
actual size of standard parts is
φ
50.009
,
When the null position of M1 is set
with this standard component, the deviation between the actual value and the
theoretical value is -1
μ
m, it is necessary to conduct supplementary
adjustment.Click
,
Type "-1" or click M1
,
Set the tuning
value to -1 to compensate the standard parts.After setting M2 to zero, click
first
switch to the M2 tuning interface, and click
Type "-
1" or click M2
,
set the tuning value to -1 to compensate the standard
parts.