PROBLEM 

CAUSE 

REMEDY 

1. Conveyor does 
not run when 
switched on. 

(1) Power plug is not properly   
connected to mains. 
(2) Power switch is not turned on. 
(3) Inappropriate power source 

(1) Inspection, correction 
 
(2) Inspection, correction 

(3) Check power source. → See p.9.

 

2. Conveyor is 
turned on, but 
motor will not 
run. 

(1) Disconnection or breakage in wiring 
(2) Conveyor speed is set too slow. 
(3) Circuit protector or emergency stop 
switch has been activated. 
(4) Failure of motor or inverter 

(1) Inspection, repair 
(2) Reset to appropriate speed. 

→ See p.9.

 

(3) Restore protection circuit or emergency 
stop switch. 
(4) Replace motor or inverter. 

3. Motor runs, 
but belt does not 
move. 

(1) Belt is slacked off. 
 
(2) Pulling springs have come off. 
(3) Chain has come off or expanded. 
(4) Liquids, oil, foreign substances, etc. 
are sticking to machine. 
(5) Overload 

(1) Replace pulling springs if they have 
expanded. 

(2) Reset pulling springs. →See p.

9. 

(3) Repair or replacement 
(4) Remove any foreign matter and clean. 
 
(5) Inspect and reduce load. 

4. Belt runs, but 
speed cannot be 
changed. 

(1) Breakage in wiring of motor and   
inverter 
(2) Failure of inverter 

(1) Inspection, repair 
 
(2) Inspection and repair or replacement 

5. Conveyor   
makes abnormal   
noise and   
vibration. 

(1) Loose fixing bolts 
(2) Rotation malfunction of sprocket 
(3) Chain has run out of oil. 
(4) Foreign substances are stuck in 
machine. 
(5) Rotation malfunction of roller 

(1) Inspect and tighten loose bolts. 
(2) inspection, replacement 
(3) Apply grease to chain. 

→See p.

12. 

(4) Inspection, cleaning 
 
(5) Inspection, replacement 

6. Electric shock 
is received from 
conveyor. 

(1) Static electricity has been charged   
in frames. 
(2) Electric leakage 

(1) Properly ground the machine.   

→ See p.9.

 

(2) Inspection, investigation 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INSPECTION AND MAINTENANCE 

7-1. PROBLEMS AND REMEDIES 

Содержание S-CON MINI CURVE SDBR

Страница 1: ...1 S CON MINI CURVE Wide Roller Edge SDBR OPERATING AND SERVICE MANUAL...

Страница 2: ...manual carefully before use Keep the manual where the machine is installed so that it may be referred to when needed TABLE OF CONTENTS 1 Caution When Handling 2 Component Names 3 Running the Conveyor...

Страница 3: ...e frequency and Belt speed eg 50Hz 16m min NOTE Maximum speed is shown Nominal belt width in cm eg 120cm Curve angle eg 90 Power source type eg 200V three phase Motor output eg 0 4kW Motor type eg Inv...

Страница 4: ...T touch electrical parts with wet hands Do NOT use in an explosive atmosphere Avoid explosive gas explosive dust etc Lower cover and guard Install the optional lower cover or guard in order to prevent...

Страница 5: ...yor Secure the conveyor to the floor ground When using the conveyor be sure to secure it to the floor ground with anchor bolts etc to prevent it from toppling irrespective of indoor use or outdoor use...

Страница 6: ...ught and injured by the conveyor ALWAYS CONNECT TO EARTH Ensure the conveyor is connected to earth at all times to prevent electric shock DISCONNECT POWER BEFORE SERVICING Ensure that the power is swi...

Страница 7: ...7 2 ATTACHMENT POSITIONS OF WARNING LABELS etc...

Страница 8: ...8 2 COMPONENT NAMES...

Страница 9: ...y lead wire terminal Before operation confirm position and function of emergency stop and that there is no dangerous place around conveyor and its movable parts 3 1 BE SURE TO GROUND MACHINE BEFORE OP...

Страница 10: ...4 Pull out belt Since belt is easy to get damaged if caught on bracket etc pull it out while covering with cardboard etc Fixing knob bolt Outside cover Inside cover NEXT release belt side hook Releas...

Страница 11: ...elt Since belt is easy to get damaged or dirty if caught on bracket etc insert it while covering with cardboard etc 2 Combine belt with chain by resetting pulling springs For each pulling spring reset...

Страница 12: ...name HI PWR Lube by DAIDO KOGYO CO LTD 1 Remove motor shaft end cap 2 Pull out hexagon socket head cap screw together with washer 3 Pull out geared motor from drive shaft 4 Remove torque arm from moto...

Страница 13: ...stances etc are sticking to machine 5 Overload 1 Replace pulling springs if they have expanded 2 Reset pulling springs See p 9 3 Repair or replacement 4 Remove any foreign matter and clean 5 Inspect a...

Страница 14: ...Overheat abnormal noise Manual check listening Inspection and adjustment or replacement Six monthly Frame stand unit Attachments Loose attachment bolts Visual inspection and manual check Inspection ad...

Страница 15: ...15 MEMO...

Страница 16: ...23 01 Particular attention is given to the manufacture and transportation of SANKI conveyors However if you need any information about the use or failure of the machine or any other matters please con...

Отзывы: