(Please note the following points when using this product.)

1

2

Use only for embedded devices.

3

4

Before using the product, please read the "Owner's Manual" and "Detailed Specification" well and use
it correctly.

This switching power source is a direct-current stabilization power source with a special structure
designed for embedded devices.

We are striving to improve the quality and reliability of our products. However, we ask our purchasers
to be responsible for designing the safety of equipment so that if this switching power source is used,
it will not infringe on life, body or property due to malfunctions or breakdowns.

This product is not intended to be used in equipment or devices that require extremely high reliability
(such as aerospace equipment, nuclear power control, and medical equipment (Class III or higher in
Japanese laws and regulations) whose failure or malfunctioning may harm lives or human bodies)
(hereinafter referred to as "application-specific").
We shall not be liable for any damage caused to our customers or third parties by using our products
for specific purposes.

1. Safety Precautions

Safety Requests

5


6




PAN40012-001E-07

Regarding the following applications and equipment that are involved in human health and have a
significant impact on the maintenance of public functions, ensure that the equipment side has
adequate fail-safe functions through the redundancy of systems and other measures.

Use in trains, elevators, and other equipment that could lead to injury or other damage to human lives.
Used in automotive, marine, and other applications and equipment that are subject to fluctuations
and shocks.
Use in transportation systems and other uses and equipment that have the potential to have a
serious social and public impact.
Use for similar applications and equipment.

Please adhere to the following guidelines when using this product.

Do not disassemble, repair, or remodel.
There is a high voltage within the power supply.
Use within the specified range of input voltage, frequency, output voltage, and current.

Installation and installation methods are determined for each model.
Do not install or install in a direction outside the designated direction.

Please strictly observe the specified environmental conditions, such as the environmental
temperature and the temperature of the environment.

PAN40012-001E-07

SANKEN ELECTRIC CO.,LTD.

3/26

Содержание SWL Series

Страница 1: ...Operation Manual SWL Series PAN40012 001E 07 PAN40012 001E 07 SANKEN ELECTRIC CO LTD 1 26...

Страница 2: ...nsional Outline Drawing P 10 4 Model Name Generic Examples Options P 18 5 Terminal Connection P 19 6 Derating P 20 7 Mounting Method P 22 8 Expected life P 24 9 Warranty period P 24 Table of Contents...

Страница 3: ...rposes 1 Safety Precautions Safety Requests 5 6 PAN40012 001E 07 Regarding the following applications and equipment that are involved in human health and have a significant impact on the maintenance o...

Страница 4: ...ake of safety the product should be handled by anyone with electrical knowledge In this book safety precautions are categorized as danger and caution If the product is used without observing the infor...

Страница 5: ...er supply Otherwise an electric shock or fire could occur We do not anticipate the use of this product in equipment that requires high reliability such as those related to human life Do not use for sp...

Страница 6: ...C100V AC240V 60Hz 0 06 0 16typ AC100V AC240V Start up time typ 1 700msec Output Condition 3 Peak Output Current A Output Current Allowable Range A Rated Output Power W Peak Output Power W Rated Output...

Страница 7: ...V 60Hz 0 05 0 15typ AC100V AC240V Rated Output Voltage V Output Voltage Variable Range V 9 Rated Output Current A 8 Peak Output Current A Output Current Allowable Range A Cooling Condition 300msec Add...

Страница 8: ...63 Power Factor typ 1 0 99 0 95 Rated Output Voltage V Output Voltage Variable Range V 9 Rated Output Current A 8 Peak Output Current A Output Current Allowable Range A Rated Output Power W Output Con...

Страница 9: ...ciency typ 1 Inrush Current typ A 2 Leakage Current mA 1 Natural Air Additional Function Over Current Protection Over Voltage Protection 6 Environmental Condition Operating Temperature Range Storage T...

Страница 10: ...Unit mm The error without instruction is 1 0mm SWL100 S 3 Dimensional Outline Drawing SWL100 L S PAN40012 001E 07 PAN40012 001E 07 SANKEN ELECTRIC CO LTD 10 26...

Страница 11: ...Unit mm The error without instruction is 1 0mm SWL100 LC S 3 Dimensional Outline Drawing PAN40012 001E 07 PAN40012 001E 07 SANKEN ELECTRIC CO LTD 11 26...

Страница 12: ...Unit mm The error without instruction is 1 0mm SWL150 S 3 Dimensional Outline Drawing SWL150 L S PAN40012 001E 07 PAN40012 001E 07 SANKEN ELECTRIC CO LTD 12 26...

Страница 13: ...Unit mm The error without instruction is 1 0mm SWL150 LC S 3 Dimensional Outline Drawing PAN40012 001E 07 PAN40012 001E 07 SANKEN ELECTRIC CO LTD 13 26...

Страница 14: ...Unit mm The error without instruction is 1 0mm SWL240 S 3 Dimensional Outline Drawing SWL240 L S PAN40012 001E 07 PAN40012 001E 07 SANKEN ELECTRIC CO LTD 14 26...

Страница 15: ...Unit mm The error without instruction is 1 0mm SWL240 LC S 3 Dimensional Outline Drawing PAN40012 001E 07 PAN40012 001E 07 SANKEN ELECTRIC CO LTD 15 26...

Страница 16: ...Unit mm The error without instruction is 1 0mm SWL300 S 3 Dimensional Outline Drawing SWL300 L S PAN40012 001E 07 PAN40012 001E 07 SANKEN ELECTRIC CO LTD 16 26...

Страница 17: ...Unit mm The error without instruction is 1 0mm SWL300 LC S 3 Dimensional Outline Drawing PAN40012 001E 07 PAN40012 001E 07 SANKEN ELECTRIC CO LTD 17 26...

Страница 18: ...tional Equipment Output Power Output Voltage 100 100W No output variable 150 150W 240 240W 100W 150W 240W 12V 24V 36V 48V 4 Model Name Generic Examples Options SWL S Type Standard Products L type Chas...

Страница 19: ...VHR 5N SVH 21T P1 1 Input 2 BVH 21T P1 1 3 AC N 4 5 FG 1 V B6P VH VHR 6N SVH 21T P1 1 Output 2 V BVH 21T P1 1 3 V 4 V 5 V 6 V NOTE 2 4 pin of CN101 nothing CN601 should be used at 5 A or less per pin...

Страница 20: ...E F SWL100 24 36 48 S PAN40012 001E 07 Output current Load Ambient temperature Reference Derating Curve Without Chassis Cover Ambient temperature Reference Derating Curve Without Chassis Cover 0 20 1...

Страница 21: ...e Derating Curve Without Chassis Cover SWL300 S PAN40012 001E 07 0 20 40 60 80 100 10 0 10 20 30 40 50 60 70 0 20 40 10 0 10 20 30 40 50 60 70 Ambient temperature Reference Derating Curve Without Chas...

Страница 22: ...001E 07 If a metal case is used secure the dimensions of A and B for the separation between the power supply and the metal case This dimension is the necessary distance for the separation and does no...

Страница 23: ...he time of installation Use a small washer W sem screw M3 as the mounting screw Hatching indicates the allowable range for the metal part of the installation on the front side of the chip The size of...

Страница 24: ...years or more 4 years Ta 25 or less 10 years or more 10 years or more Conditions for use of the free warranty range Ta 50 or less 7 years 6 years Ta 35 or less 9 years 8 years SWL150 S A Ta 50 or less...

Страница 25: ...PAN40012 001E 07 SANKEN ELECTRIC CO LTD 25 26...

Страница 26: ...n 530 0001 Japan Phone 81 3 3986 6151 Phone 81 6 6450 4400 Inquiry by E mail sw power sanken ele co jp PAN40012 001E 07 This promotion sheet is as of October 2020 Please note that the contents are sub...

Отзывы: