15
NOTE:
It is possible to have two types of rubber blades. Para
rubber blades for all types of floors and polyurethane
rubber blades for mechanical workshop floors which are
dirty with oil.
7.2 Squeegee set up (correct position)
(Fig. 22)
• Lower the squeegee using the squeegee lever.
• Start the vacuum and move forward several feet before
stopping the suction unit and the machine.
• Check the angle of the rubber blades (1) on the floor.
Fig. A = too low
Fig. B = too high
Fig. C = correct position
• Remove the squeegee unit from the machine
• To reposition the blade, loosen the screw (2) of the wheel
(3) and move the wheel vertically in the slot lifting or lower-
ing the wheel, to achieve the correct
position (C).
Fig 21
Fig 22
7.3 Changing the brush or pad driver
• Lift the machine up slightly at the front
• Press the brush rotation button (3) to enable the rotation
of the brush, then press lever (5) and release it; the brush
becomes disconnected (Fig 23)
7.4 Replacing the fuses (Fig 24)
WARNING
Replace the blown fuse with one
with the same amperage.
• Unscrew the two bolts (1) that fasten the external box
(2) and remove it.
• Unscrew the two bolts (3) of the printed circuit board
(4) and remove it.
• Replace Fuse (5) Green 30A
• Reverse steps above to replace components after
fuse is replaced.
(Fig 23)