Document No. 98-1133F4 • September 2019 • ©2019 Atlantic Ultraviolet Corporation

®

Read and Follow All Safety Instructions. Save These Instructions.

Installation, Operation & Maintenance

Model RSCS280A

Extensive Product Information Available at: 

Ultraviolet.com

BuyUltraviolet.com

Owner

s Manual

Owner

s Manual

Содержание RSCS280A

Страница 1: ...ntic Ultraviolet Corporation Read and Follow All Safety Instructions Save These Instructions Installation Operation Maintenance Model RSCS280A Extensive Product Information Available at Ultraviolet com BuyUltraviolet com Owner s Manual Owner s Manual ...

Страница 2: ...oom Air Sanitizer Model RSCS280A Questions that are not specifically answered by these instructions should be directed to the Factory Atlantic Ultraviolet Corporation takes all possible precautions when packaging equipment to prevent damage Carefully inspect and report all damages immediately Do not install damaged equipment Follow all instructions on any labels or tags Carefully inspect all packi...

Страница 3: ...DANGER WARNING No 00 0195A2 UV ULTRAVIOLET RADIATION Protect eyes and skin from direct and reflected radiation DANGER Turn off and disconnect power before servicing HAZARDOUS VOLTAGE No 00 0197A2 AIR WATER Part No 00 0195A2 2 75 x 1 5 Part No 00 0197A2 2 75 x 1 5 AIR Part No 00 0198A1 1 25 x 3 This fixture is designed for use with germicidal ultraviolet lamps and must be installed in compliance wi...

Страница 4: ...sure constructed of stainless steel Stainless steel construction provides strength durability and will withstand most harsh environments An interlock safety switch The interlock switch interrupts power to the sanitizer when the access door is opened from the lamp exposure chamber Principle of Operation The SANITAIRE Room Air Sanitizer is categorized as a germicidal ultraviolet fixture that utilize...

Страница 5: ... The SANITAIRE Model RSCS280A Room Air Sanitizer includes 1 Model RSCS280A 120v 50 60Hz 1 4 High Output STER L RAY Germicidal Ultraviolet Lamps may be packed within the unit INSTALLATION Fixture Placement The SANITAIRE Model RSCS280A fixture is recommended for use in rooms with suspended T Bar ceilings Access to the room does not need to be controlled while the fixture is operating The exposure ch...

Страница 6: ...onditions surrounding each installation It is recommended that the ultraviolet lamps be cleaned at least once every three 3 months The STER L RAY Germicidal Ultraviolet Lamps used in the SANITAIRE have a manufacturer s rated average effective life of 13 000 hours Lamps may operate longer than their rated effective life but the reduction in ultraviolet output will make it impractical to use past th...

Страница 7: ...lamp by the base and carefully pull the lamp away from the connector while removing pressure off the STER L RAY lamp from the end supports See Figure 3 4 Once the lamp is clear from the connector carefully lift STER L RAY lamp away from the far end support and remove STER L RAY lamp from the unit See Figure 4 5 Repeat until all STER L RAY lamps have been removed from the unit Figure 4 Figure 3 6 M...

Страница 8: ...fully push the STER L RAY lamp into the connector See Figure 7 12 Once the STER L RAY lamp is securely seated into the connector carefully push the STER L RAY lamp into the end support See Figure 8 13 Repeat until all STER L RAY lamps have been installed into the unit Avoid exposure to direct or reflected germicidal ultraviolet rays Germicidal ultraviolet rays are harmful to the eyes and skin 14 C...

Страница 9: ...ater either by immersing or with a fine spray in the direction opposite to the airflow If the filter is contaminated with heavy grease concentrations wash filter with a detergent solution NOTE Follow all manufacturer s instructions and precautions for handling detergents The filter should be rinsed thoroughly with clean water 6 Shake off any excess water from PromateTM filter and let dry 7 Replace...

Страница 10: ...nce Use personal protection equipment such long sleeves with no gaps between cuffs and gloves and ultraviolet resistant face shield if troubleshooting SANITAIRE IMPORTANT This unit is to be serviced ONLY by qualified and appropriately trained and or licensed personnel Table 1 Troubleshooting Problem Possible Cause Corrective Action Unit not operating No electrical power Verify that the unit is con...

Страница 11: ...s for 4 Lamps 88W Weight Pounds lbs 64 lbs j Fixture capacity incorporates an estimated allowance for airflow friction loss across filter and fixture k Wattage is lamp watts only and does not include ballast loss l Ultraviolet output at 254nm at 100 hours and 80 F approximate All specifications dimensional data etc are approximate and subject to change without notice REPLACEMENT PARTS Table 3 Repl...

Страница 12: ...l notify us at our main office in writing of claims including claims of breach of warranty within thirty 30 days after the Buyer discovers or should have discovered the facts upon which the claim is based Failure of the Buyer to give written notice of a claim within the time period shall be deemed to be a waiver of such claim The provisions of the above warranty are our sole obligation and exclude...