9. When installing the new lamps, carefully examine the pin configuration on the lamps base to ensure that the lamp is installed
correctly into the lamp connector (See
Figure 5
, which shows the lamp connector and
Figure 6
, which shows the lamp base,
below).
10. Begin installing the
STER-L-RAY
®
lamps from one side and continue to the next until all
STER-L-RAY
®
lamps have
been installed.
11. Hold the
STER-L-RAY
®
lamp by the base and carefully push the
STER-L-RAY
®
lamp into the connector. (See
Figure 7
)
12. Once the
STER-L-RAY
®
lamp is securely seated into the connector, carefully push the
STER-L-RAY
®
lamp into the end
support. (See
Figure 8
)
13. Repeat until all
STER-L-RAY
®
lamps have been installed into the unit.
Avoid exposure to direct or reflected germicidal ultraviolet rays. Germicidal ultraviolet
rays are harmful to the eyes and skin.
14. Close and lock access door.
15. Restore power to the fixture.
16. Verify operation by viewing Lamp Operation Indicators (LEDs). If the sanitizer is not operating properly, go to
“Troubleshooting”
section.