11
NO.
DESCRIPTION
QTY
PART NO.
1
Germicidal Ultraviolet Lamp
4
05-1352-R
2
Electronic Ballast, 120v 50/60Hz
4
10-0137
Electronic Ballast, 230v 50/60Hz
4
10-0136
3
Lamp Holder Set
4
05-1320A
4
Interlock Switch, SPDT
1
40-4040A
5
Air Filter, Electrostatic, Washable, 6"x20"x1"
1
40-0062A
6
Blower, 140CFM, 120v 50/60Hz
2
40-1079B
Blower, 140CFM, 220v 50/60Hz
2
40-0031A
7
Eyebolt, 8-32 x 1" Long with Hex Nut
4
50-0157
8
Lead Cord, 120v
1
35-1100
Lead Cord, 220v - 240v
1
35-1452
REPLACEMENT PARTS
Table 3 - Replacement Parts for Model RSCS280
Other replacement parts are available. Consult the Factory for specific requirements.
TECHNICAL SPECIFICATIONS
Table 2 - Technical Specifications
Blower Capacity: (Cubic Feet per Minute)
280
Nominal Fixture Capacity
c
: (Cubic Feet per Minute)
210
Max Treatment Capacity: (Cubic Feet per Hour)
12,600
Max Room Size @ 3 Air Changes/Hour: (Cubic Feet)
4,200
Max Room Size @ 4 Air Changes/Hour: (Cubic Feet)
3,150
Max Room Size @ 5 Air Changes/Hour: (Cubic Feet)
2,520
Max Room Size @ 6 Air Changes/Hour: (Cubic Feet)
2,100
Dimensions:
Length: (Inches)
46-5/8
Width: (Inches)
22-1/8
Height: (Inches)
9-7/16
Electrical:
Volts: (Volts)
120
220-240
Amps: (Amps)
4.4
2.32
Line Frequency: (Hertz)
60
50
Lamp Data:
Power Consumption
d
: (Watts/Lamp)
32
Ultraviolet Output
e
: (Watts/Lamp)
11.2
c
Fixture capacity incorporates an estimated allowance for airflow friction loss across filter and fixture.
d
Wattage is lamp watts only and does not include ballast loss.
e
Ultraviolet output at 254nm at 100 hours and 80
°
F (approximate).
All specifications, dimensional data, etc. are approximate and subject to change without notice.