Emptying Machine 
 

Prior to the disassembly and cleaning of parts, the 
machine must be emptied of product. Use the following 
procedures (Steps 1 through 3). If this is first time 
operation, disregard these steps. 
 

DO NOT INSERT ANY OBJECTS OR TOOLS INTO 
THE MIX INLET HOLE, CARBURETOR TUBE HOLE, 
OR FRONT PLATE DISPENSING HOLE WHILE THE 
MACHINE IS RUNNING.  DAMAGE TO THE 
MACHINE OR PERSONAL INJURY MAY RESULT. 
 

1.  Remove the carburetor tube (Fig. 3) from the mix 
inlet hole and lay in the bottom of the mix pan. 
 
2.  Set the control switch to the 

“CLEANOUT” 

position 

and dispense all product from the freezing cylinder by 
pulling downward on the spigot handle (Fig. 4) to empty 
the machine. 
  
3.  Set the control switch to the 

“OFF” 

(center) position. 

Close the spigot handle before proceeding to cleaning. 

 

Disassembly and Cleaning Procedure 
 

1.  Fill the machine with cold water and set the control 
switch to the 

“CLEANOUT” 

position. 

DO NOT 

use 

hot water which could damage the machine.  Let the 
machine agitate briefly and drain the water by pulling 
downward on the spigot handle.  After the machine is 
empty, set the control switch to the 

“OFF” 

position. 

Repeat the above procedure as necessary to make 
certain that all product is removed from the machine. 
 
2.  Prepare a suitable detergent and water solution at a 
temperature of 125

°

 to 130

°

 F. 

DO

 

NOT 

use an 

abrasive detergent on any part of the dispenser. 

DO NOT USE HOT WATER 

DOING SO COULD DAMAGE YOUR MACHINE 

 

3.  Fill the mix pan with the cleaning solution.  Make 
certain that the machine is 

“OFF”.  

Clean the mix pan 

thoroughly with a brush as the solution drains into the 
freezing cylinder.  Clean the mix inlet tube and the 
carburetor tube holes with the brush provided.

 

Disassembly & Cleaning 

 

CONSULT YOUR LOCAL HEALTH AGENCY FOR CLEANING AND SANITIZING REQUIREMENTS. 
 

This unit does not come presanitized from the factory. Before serving product, the dispenser must be disassembled, 
cleaned, lubricated, and sanitized. These instructions are general guidelines only. Cleaning and sanitizing procedures 
must conform to local health agency requirements.

 

WARNING

 

    

DISASSEMBLY & CLEANING 

Fig. 3 

Carburetor Tubes 

Shake 

Carb Tube 

Fig. 4 

Dispensing Product 

PAGE  3 

IMPORTANT

 

SoftServe 

Carb Tube 

O-Ring 