12
NO POWER / NOT OPERATING
1) Power Supply
Note: Recommended that all electrical service connections be made by a licensed electrician.
a. Ensure switch box power cord is properly plugged into an operational 115 VAC, GFCI power supply.
b. For 230 V units with junction box, verify hard wire connections are secure.
c. Check GFCI reset and circuit breakers for 115 V or 230 V units.
2) Dry Run Sensor Reset
Note: A dry run sensor automatically resets the Pipeless™ Pedicure Bath if no water is present, or if unit had been
inadvertently turned or left on.
a. DO NOT OPERATE JET SYSTEM WITHOUT WATER FILLED AT LEAST 1 in (3 cm) ABOVE THE JETS.
b. Reset the motor by unplugging the system, waiting 5 seconds, then plugging system back in again.
3) Jet Assembly Alignment
a. Check jet assembly is locked in the 9 o’clock or 3 o’clock “run” position in the jet motor case.
b. Ensure magnetic impeller rotor is correctly installed in the jet motor case.
c. Inspect separator plate to ensure proper assembly in the jet escutcheon.
d. Inspect separator plate to ensure magnets (2) are present and properly installed.
EXCESSIVE NOISE
1) Remove jet assembly (escutcheon and separator plate) and inspect for dirt buildup, debris or damage. Clean or
replace if necessary.
2) Remove magnetic impeller rotor and inspect for dirt buildup or debris. Clean or replace if necessary.
3) Switch impeller rotor to other jet to test.
Note: Jet assembly must be reassembled and water refilled 1 in (3 cm) above jets for proper test.
4) If noise persists, contact your distributor for motor replacement information.
Troubleshooting