background image

9

Operating Instructions

1.  After the pedicure bath has been properly installed, fill the unit with water, at the desired temperature, 1 in (3 cm) above 

the jets.

2.  Verify that the unit’s electrical cord is connected to a GFCI protected electrical outlet.

3.  To start or stop this appliance turn the dial switch to the ON or OFF position.

4.  Bath additives , including oil based products , can be used in a SANIJET Pipeless™ Pedicure Bath, since their residue can 

be easily cleaned. CAUTION: Use only low foaming additives, and do not use products that contain sand or silicates.

5.  You should always be in a seated position when placing your feet into or removing them from the pedicure bath.
  WARNING: NEVER STAND IN THE PEDICURE BATH BASIN.

Quarter-turn Counter Clockwise

Содержание PIPELESS SSB2-S115-XX

Страница 1: ...Purity is Premium PIPELESS PEDICURE BATH OWNER S MANUAL Models SSB2 S115 XX 115v 60Hz Models SSB2 S230 XX 230v 50Hz ...

Страница 2: ...ility for quick and easy system disinfection Please read and follow all of the instructions contained in this Manual before installing operating or maintaining your new SANIJET Pipeless pedicure bath Before proceeding please take a few minutes to complete the warranty registration enclosed in your Owner s packet and submit it to SANIJET at the address provided on the form If you have questions con...

Страница 3: ...y 2 Safety 3 Features and Specifications 4 Installation Electrical 5 Installation Standard Self Rimming 6 How to Remove for Service 8 Operating Instructions 9 Dry Run Protection 10 SANIJET Pipeless Disinfection 11 Troubleshooting 12 Table of Contents ...

Страница 4: ...t do not install the unit SANIJET s responsibility for shipping damage ceases upon delivery of the product in good condition to the carrier It is the responsibility of the recipient to inspect the packaging for damage Any damage claims must be filed with the carrier within 2 business days from receipt of shipment All returns will be refused unless accompanied by a Return Material Authorization RMA...

Страница 5: ... This warranty does NOT cover a metallic plated hardware light bulbs or fading from exposure to direct sunlight b failure damage or defect caused by any of the following after the product leaves SANIJET s factory mishandling abuse misuse neglect accident or natural disaster normal wear and use that does not affect the product s function failure to maintain the product as recommended by SANIJET See...

Страница 6: ...en into water Unplug immediately 2 DO NOT drop or insert anything into any jet opening 3 DO NOT operate this unit without the complete jet assembly installed or without water filled 1 in 3 cm above the jets 4 DO NOT overfill the basin 5 DO NOT stand on or in the basin or on the foot rest 6 DO NOT leave this appliance unattended when in operation 7 Keep the electrical cord away from heated surfaces...

Страница 7: ... 66 cm 25 5 23 cm 9 7 cm 2 5 49 cm 19 66 cm 25 5 23 cm 9 66 cm 25 5 7 cm 2 5 30 cm 12 11 cm 4 Width 19 0 49 cm x Length 25 5 49 cm x Height 12 0 30 cm Material Structurally reinforced cast acrylic Operating Capacity 4 5 Gallons 17 L Approximate Ship Weight 42 lbs 19 kg Water Flow Rate 14 gallons per minute 53 L Electrical Requirements SSB2 S115 115 V 60 Hz 2 Amp 3 foot power cord NEMA 5 15 plug ET...

Страница 8: ...accessible for easy access for plugging or unplugging 3 foot power cord prior to unit service Power cord should be positioned as to not contact floor of pedicure unit s enclosure Turn off circuit breaker before installing or removal of unit or servicing electrical components 230 V 50 Hz unit is provided with a 2 x4 junction box with three bare leads for hard wire connections Conductor Insulation c...

Страница 9: ...n request 3 Install Drain Assembly a If using DK D100 purchased separately from SANIJET install the drain assembly on the pedicure bath See Image 3 Apply a bead of plumber s putty to the underside of the strainer body to prevent water from seeping under its chrome plate Secure the drain and seal beneath the drain hole in the pedicure sink by screwing in the strainer body Tightly thread the straine...

Страница 10: ...round the finished edge of the pedicure bath to prevent moisture from entering between the bath and mounting platform Wipe away any excess caulk 7 Connect the drain assembly to the piping of the drain outlet 8 Establish Electrical Connection See Electrical Connections section on Page 5 for 115 V 60 Hz or 230 V 50 Hz connection instructions 9 Install your choice of faucetry 4 There are four mountin...

Страница 11: ...rs or ChromaSoothe lights To remove bath from a mounting platform that DOES NOT provide access under the unit 1 Cut away any visible caulk from around the deck of the unit 2 Removethedraincoverfromthestrainerbodybyremovingthechromeknobonthedraincover twistcounterclockwise Insert a flat ended screwdriver into the brass fitting revealed when the knob is removed Unscrew the drain cover from the strai...

Страница 12: ...ppliance turn the dial switch to the ON or OFF position 4 Bath additives including oil based products can be used in a SANIJET Pipeless Pedicure Bath since their residue can be easily cleaned CAUTION Use only low foaming additives and do not use products that contain sand or silicates 5 You should always be in a seated position when placing your feet into or removing them from the pedicure bath WA...

Страница 13: ...n back ON If the motor does not sense a load after 8 seconds it will shut off again for another 15 seconds The motor will repeat this sequence a total of 10 times before going into standby mode Resetting the motor requires cycling the main power to the motors OFF and then back ON unplug system and wait 5 seconds then plug power supply back in again SAFETY SHUTOFF SENSOR The Pipeless Pedicure Bath ...

Страница 14: ...requiring quick cleaning between treatments we recommend a second set of clean jet assemblies for quick replacement IMPORTANT Always refer to your state and local guidelines for cleaning requirements NEVER USE abrasive cleaners on any surface area After each use disinfect the system with the recommended disinfection procedures for maximum sanitation BEFORE USE check the jet assembly is properly in...

Страница 15: ...econds then plugging system back in again 3 Jet Assembly Alignment a Check jet assembly is locked in the 9 o clock or 3 o clock run position in the jet motor case b Ensure magnetic impeller rotor is correctly installed in the jet motor case c Inspect separator plate to ensure proper assembly in the jet escutcheon d Inspect separator plate to ensure magnets 2 are present and properly installed EXCE...

Страница 16: ...111223 SANIJET Customer Service Department Toll Free 877 934 0477 Toll Free Fax 214 352 0348 E mail info sanijet com 6200 Maple Avenue Dallas Texas 75235 sanijet com ...