5. Installation
Sanipack is designed to fi t behind panelling, and should be installed by a qualifi ed person.
WARNING: The unit must be connected to a WC pan with a horizontal outlet spigot
The Sanipack has fastenings preventing it turning or from moving.
Warning:
Provide an access panel of the following dimensions to enable the unit to be removed for possible service:
L= 400mm x H = 400mm if the side inlets are not utilised
L= 500mm x H = 500mm if the side inlets are utilised
Warning: A screwdriver or other tool should be required to remove the access panel.
Please note:
The SANIFLO range of pumps / macerators are fi tted with thermal cut out protection.
In the event of continuous water fl ow into the unit over a long period E.G a tap left running the motor will cut out to prevent damage and then
self reset when it has cooled down (after 30 minutes).
ø 22/28/32
DN 40
DN 20
DN 32/40
400mm
400mm
500mm
400mm
120mm min