11. In case a service is needed

Allow for a drain-off point at the bottom of the rising 
discharge pipe. Ensure that the unit is easily accessible 
for possible maintenance.

13. Standard

Sanicom conforms to Standard EN 12050-2. Lifting station for waste products not containing faecal matter.

SANICOM®

Société Française d’Assainissement

EN 12050-2/03

FF03-P95
220 - 240 V - 50 Hz - 750 W - IP44

12. Electrical connection

14. Alarm

There is the option of connecting an alarm (light, bell) 
on to the electronic circuit board (2 terminals fed  
with 220V). If the motor is run continuously (more than 
5 minutes), the contact will be made. This enables the 
user to carry out a check if he wishes.

Connection of the alarm

Two 6.35 push on connection points are available on the 
electronic circuit board (arrowed) for creating an alarm 
circuit. (These connectors have a 220V, 0.5A maximum 
current passing through them). To access them after 
turning the power off, remove the cover then unscrew 
and unclip the upper casing of the electronic box, to 
expose the electronic circuit board. On this card use the 
point marked 

E.V.

 and the unused neutral connection 

point marked

 N.

 Use a round 2 x 0.75mm 2 wire, which 

must pass across the lid of the upper casing, through the 
cable gland, before being connected to the chosen alarm 
system.

 

The electrical installation should be carried out by a qualified person.

All wiring must conform to BS7671, 1992 requirements for electrical installations. The Sanicom requires a 
220/240V single phase AC 50 Hz supply (UK specification). Do not connect the Sanicom to a conventional plug and 
socket. It must be wired into a fused, unswitched, fixed wiring connector fitted with a 5 amp fuse. The Sanicom 
has an earth wire. The wires in the mains lead are coloured in accordance with the following code:

Brown – Live       Blue – Neutral       Green/Yellow – Earth

Warning:

 Ensure the electricity is turned OFF at the main switchboard before wiring to connector.

All work on cable, pressure chamber and motor should only be carried out by a qualified Saniflo servicing agent, 
as special tools are required.

UK – 230/240V 50Hz.

The unit should be installed so it is easily accessible/removable for possible maintenance.  
The unit should not be exposed to splashing in normal use.

CANADA
USA

EUR

CH

GB

Содержание Sanicom FF03-P95

Страница 1: ...e safety of persons Indication that a risk of electrical origin exists Electrical installation must be carried out by a professional electrician Attention Failure to comply with this instruction could endanger the safe functioning of the apparatus 2 List of Accessories included 25 x 40 A B C D E F G H I x2 x1 x2 x2 x1 x1 x2 x2 x1 Hose clip Hose clip Inlet Cover Hose clip Screw Plug Elbow Hose clip...

Страница 2: ...aste enters the unit As soon as the waste enters the tank the pump starts 5 Performance Curve Height and Length of the discharge pipe Flow Rate litre min Vertical Height Metres 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 12 11 10 9 8 7 6 5 4 3 2 1 0 max 10m 3 7 4m 3m 2m 1m 5m 6m 7m 1 Max 8m max 20m max 30m max 40m max 50m max 60m max 70m max 80m 420mm 330mm 490mm ø 60 230mm ...

Страница 3: ... Maximum current consumption 3 3 A Electrical class I Protection index IP44 Max temp with intermittent functioning 80 Net weight 10 kg In the case of bath or shower tray make sure the waste traps are raised 15cm above floor level CAUTION 1 All applications other than those described in this notice are prohibited 2 Do not exceed an incoming flow rate greater than 80 of the flow rate stated on the d...

Страница 4: ...a vertical rise is required this must be installed at the start of the run before the horizontal section The horizontal section should then have a minimum 1 fall to the final drain point Take care that the discharge valve flap faces the direction of flow If the end of the discharge pipework is much lower than the unit install a riser pipe about 80mm long from the highest point of the discharge run...

Страница 5: ...ronic circuit board On this card use the point marked E V and the unused neutral connection point marked N Use a round 2 x 0 75mm 2 wire which must pass across the lid of the upper casing through the cable gland before being connected to the chosen alarm system The electrical installation should be carried out by a qualified person All wiring must conform to BS7671 1992 requirements for electrical...

Страница 6: ...s Pump is blocked Pump Jammed To much water flowing through Call a service engineer Call a service engineer Reduce water inflow ELECTRICAL INSTALLATION MUST BE CARRIED OUT BY A PROFESSIONAL ELECTRICIAN Before carrying out any service work always disconnect power supply SYMPTOMS PROBABLE CAUSES REMEDIES Motor does not start Pressure reader tube kinked or out of position Electronic card defective Ch...

Страница 7: ...19 Parts ...