background image

1. Description

Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit 
operates automatically, has a high performance level, and is safe and reliable, provided all the rules for installation and maintenance in this 
notice are strictly followed. Especially those indicated by:

 

Failure to comply with this instruction could endanger the safety of persons

 

Indication that a risk of electrical origin exists

 

Electrical installation must be carried out by a professional electrician. 

“Attention”

 

Failure to comply with this instruction could endanger the safe functioning of the apparatus.

2. List of Accessories included

25 x 40

A

B

C

D

E

F

G

H

I

x2

x1

x2

x2

x1

x1

x2

x2

x1

Hose clip

Hose clip

Inlet Cover

Hose clip

Screw

Plug

Elbow

Hose clip

Flexible inlet connector

For any additional information, please contact our customer service department.

32 x 50

50 x 70

40 x 60

Please also see “10 golden rules” for correct Saniflo installation on www.saniflo.co.uk

Содержание Sanicom FF03-P95

Страница 1: ...e safety of persons Indication that a risk of electrical origin exists Electrical installation must be carried out by a professional electrician Attention Failure to comply with this instruction could endanger the safe functioning of the apparatus 2 List of Accessories included 25 x 40 A B C D E F G H I x2 x1 x2 x2 x1 x1 x2 x2 x1 Hose clip Hose clip Inlet Cover Hose clip Screw Plug Elbow Hose clip...

Страница 2: ...aste enters the unit As soon as the waste enters the tank the pump starts 5 Performance Curve Height and Length of the discharge pipe Flow Rate litre min Vertical Height Metres 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 12 11 10 9 8 7 6 5 4 3 2 1 0 max 10m 3 7 4m 3m 2m 1m 5m 6m 7m 1 Max 8m max 20m max 30m max 40m max 50m max 60m max 70m max 80m 420mm 330mm 490mm ø 60 230mm ...

Страница 3: ... Maximum current consumption 3 3 A Electrical class I Protection index IP44 Max temp with intermittent functioning 80 Net weight 10 kg In the case of bath or shower tray make sure the waste traps are raised 15cm above floor level CAUTION 1 All applications other than those described in this notice are prohibited 2 Do not exceed an incoming flow rate greater than 80 of the flow rate stated on the d...

Страница 4: ...a vertical rise is required this must be installed at the start of the run before the horizontal section The horizontal section should then have a minimum 1 fall to the final drain point Take care that the discharge valve flap faces the direction of flow If the end of the discharge pipework is much lower than the unit install a riser pipe about 80mm long from the highest point of the discharge run...

Страница 5: ...ronic circuit board On this card use the point marked E V and the unused neutral connection point marked N Use a round 2 x 0 75mm 2 wire which must pass across the lid of the upper casing through the cable gland before being connected to the chosen alarm system The electrical installation should be carried out by a qualified person All wiring must conform to BS7671 1992 requirements for electrical...

Страница 6: ...s Pump is blocked Pump Jammed To much water flowing through Call a service engineer Call a service engineer Reduce water inflow ELECTRICAL INSTALLATION MUST BE CARRIED OUT BY A PROFESSIONAL ELECTRICIAN Before carrying out any service work always disconnect power supply SYMPTOMS PROBABLE CAUSES REMEDIES Motor does not start Pressure reader tube kinked or out of position Electronic card defective Ch...

Страница 7: ...19 Parts ...