13. Fault Finding / Remedies
For the most part any inconsistencies in the operation of the unit will be minor and easily rectifi ed. Please refer to the chart below.
If the problem cannot be easily remedied in this way. Please call our Service organisation.
IN ALL CASES, YOU MUST DISCONNECT THE MACERATOR FROM THE POWER SUPPLY
ALL WORK INVOLVING DISMANTLING OF THE APPLIANCE MUST BE CARRIED OUT BY AN APPROVED REPAIR AGENT
SYMPTOMS
PROBABLE CAUSES
REMEDIES
• The unit stops
• An object is blocking the blades
• The unit has been running for too long and the
(self re-setting) thermal cut out has engaged
• Call approved service engineer
• The unit will reset itself
• The motor intermittently activates
• The connected fi xtures are dripping
• The non-return valve is faulty
• Check the installation upstream
• Clean or replace the non-return valve
(externally mounted)
• The water in the WC pan goes down very
slowly and is pumped away in bursts
• The air vent (under carbon fi lter) is clogged up
• The WC pan is partially blocked
• Clear the air vent
• Clear pan
• The motor operates normally, but continues to
run for a long time
• The length or height of the installation is
over the specifi cation, or there are too many
bends/elbows
• The pump chamber is blocked
• Check the installation
• Call approved service engineer
• The motor does not activate
• The electrical power supply is not active
• The motor or the control system is defective
• Restore the electrical supply
• Call approved service engineer
• The motor emits a rattling or crunching sound,
hums, but does not run
• Foreign object in the box
• Problem with the motor or the control system
• Call approved service engineer
• Cloudy water comes up into the shower tray
(units with side inlets)
• Shower installed too low as compared with the
macerator unit
• Hinged side inlet discs clogged up
• Check the installation
• Clean the hinged discs (see section 17)
• Call approved service engineer
7. Electrical connection
The electrical installation should be carried out by a registered electrician.
it has a three pin moulded plug attachment. All wires in this cable are colour coded in accordance with
International colour coding ie BROWN - ACTIVE ( LIVE), BLUE - NEUTRAL, GREEN / YELLOW - EARTH.
• All wiring connections and GPO locations must conform to AS/NZS 3000:2007 requirements.
• Supply must be protected via a 30mA RCD rated at 16amps, located at the switchboard.
• If a decision is made to hard wire, in the event that servicing is requried then cost to disconnect and re-connect will be at consumers expense.
TO BE UNDERTAKEN BY A REGISTERED ELECTRICAL CONTRACTOR IN CONJUNCTION WITH : AS/NZS 3000.2007
8. Commissioning the Macerator Pump
BEFORE COMMISSIONING THE PUMP MAKE SURE ALL CONNECTIONS ARE SECURE AND WATER-TIGHT
Once ALL connections are secure and before you switch the power on, press the full ush button on your cistern and allow water to enter
and begin discharging into the discharge pipe system. Initial run time is normally between 5 -10 secs. Duration of run time is generally
determined by the length of travel in the pump-out line and type of waste, Pump operation will shut down after this time. Should the pump
continue running for longer than the recommended time, an installation or manufacturing problem may exist, immediately contact SANIFLO
on 03 9543 3891 and speak with a tech. support person, they will be only too happy to assist.
A lifting plant for waste water containing faecal matter and for limited applications, and to European directives and standards applicable to
Electrical and electromagnetic compatibility.
Sanipro®
Société Française d’Assainissement
EN 12050-3
LA01-x10
220 - 240 V - 50 Hz -550 W - IP44 2.9A - - 5.4 KG
9. Approvals
10. Care and use
DO NOT... dispose of sanitary materials, plastics, wood, solvents, paints, turps, caustic acid, or other corrosive acids or cleaners.
DO NOT... dispose of hot water in excess of 40º C.
DO...
DO...
previous operation, sooner rather than later.
11. Servicing
12. Warranty
ATS 5200.101
Certificate No. 23048
Manufacturer: SFA
Brand: Saniflo
The Macerator Pump is equiped with a 3 core electrical cable which contains Earth Active and Neutral wires,
The Macerator Pump requires a 240V single phase 50 Hz AC power suppl
y.
The Macerator Pump conforms to Australian and New Zealand standards AS/NZS and Watermark approvals.
DO NOT... use Blu Loo or similar products with your Sanipro as this may cause the pump to cavitate. Cavitation occurs when there is an
excessive build of of foam or froth from detergents; this may cause motor damage.
DO...
periodically clean the Macerator Pump with a basic household detergent cleaner ie domestos, pine o clean or actizyme.
Periodical servicing may be required, depending on your usage cycle. On average we would recommend that a service be undertaken every
2 years or alternatively if you believe that your Sanipro is not functioning as it has been, then give our Technical department a call to
obtain details of your nearest Service Agent.
A 2 Yr Manufacturers Warranty applies to your Sanipro pump this commences from the date of purchase and is subject to CORRECT
INSTALLATION and CORRECT USAGE. Any failure or motor burn-out attributed to incorrect installation or consumer misuse is NOT covered
under this Warranty.